Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
395
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0412 # 09 Y:1993 | 09 | 1993 | USE SYNTHETIC LUBRICANT | $1,426 | $0 | Not Implemented |
KU0412 # 10 Y:1993 | 10 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $548 | $946 | Implemented |
KU0411 # 01 Y:1993 | 01 | 1993 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $57,570 | $375,000 | Not Implemented |
KU0411 # 02 Y:1993 | 02 | 1993 | COVER OPEN TANKS | $17,260 | $11,104 | Implemented |
KU0411 # 03 Y:1993 | 03 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $10,681 | $35,000 | Not Implemented |
KU0411 # 04 Y:1993 | 04 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,229 | $710 | Implemented |
KU0411 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $294 | $171 | Implemented |
KU0411 # 06 Y:1993 | 06 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $976 | $1,200 | Implemented |
KU0411 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $757 | $221 | Implemented |
KU0411 # 08 Y:1993 | 08 | 1993 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $527 | $1,000 | Not Implemented |
KU0411 # 09 Y:1993 | 09 | 1993 | USE SYNTHETIC LUBRICANT | $181 | $85 | Implemented |
KU0409 # 01 Y:1993 | 01 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,324 | $264 | Implemented |
KU0409 # 02 Y:1993 | 02 | 1993 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $407 | $0 | Implemented |
KU0409 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $476 | $2,430 | Implemented |
KU0409 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $382 | $559 | Implemented |
KU0409 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $346 | $410 | Implemented |
KU0409 # 06 Y:1993 | 06 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $104 | $30 | Implemented |
KU0410 # 01 Y:1993 | 01 | 1993 | UPGRADE OBSOLETE EQUIPMENT | $11,139 | $4,300 | Not Implemented |
KU0410 # 02 Y:1993 | 02 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,103 | $8,550 | Not Implemented |
KU0410 # 03 Y:1993 | 03 | 1993 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $2,797 | $7,300 | Not Implemented |
KU0410 # 04 Y:1993 | 04 | 1993 | INSULATE BARE EQUIPMENT | $1,730 | $3,154 | Not Implemented |
KU0410 # 05 Y:1993 | 05 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $810 | $57 | Not Implemented |
KU0410 # 06 Y:1993 | 06 | 1993 | INSTALL OCCUPANCY SENSORS | $471 | $1,650 | Not Implemented |
KU0410 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $380 | $748 | Not Implemented |
KU0410 # 08 Y:1993 | 08 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $324 | $201 | Not Implemented |