Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
112
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0319 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $360 | Implemented |
KU0319 # 02 Y:1990 | 02 | 1990 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $6,698 | $1,200 | Implemented |
KU0319 # 06 Y:1990 | 06 | 1990 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $832 | $487 | Implemented |
KU0315 # 01 Y:1990 | 01 | 1990 | RECOVER AND REUSE COOLING WATER | $4,123 | $7,000 | Implemented |
KU0315 # 05 Y:1990 | 05 | 1990 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,282 | $100 | Implemented |
KU0316 # 07 Y:1990 | 07 | 1990 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $117 | $0 | Not Implemented |
KU0316 # 04 Y:1990 | 04 | 1990 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,990 | $7,200 | Not Implemented |
KU0316 # 06 Y:1990 | 06 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,034 | $1,000 | Implemented |
KU0319 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,125 | $0 | Implemented |
KU0316 # 03 Y:1990 | 03 | 1990 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,122 | $15,000 | Implemented |
KU0319 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $604 | $400 | Implemented |
KU0316 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $924 | $1,005 | Implemented |
KU0319 # 01 Y:1990 | 01 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,684 | $2,597 | Not Implemented |
KU0316 # 05 Y:1990 | 05 | 1990 | OPTIMIZE PLANT POWER FACTOR | $2,160 | $2,250 | Implemented |
KU0319 # 04 Y:1990 | 04 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $168 | $400 | Implemented |
KU0315 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $1,130 | $640 | Implemented |
KU0315 # 04 Y:1990 | 04 | 1990 | OPTIMIZE PLANT POWER FACTOR | $518 | $900 | Not Implemented |
KU0316 # 01 Y:1990 | 01 | 1990 | INSTALL SET-BACK TIMERS | $3,487 | $2,075 | Implemented |
KU0315 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $862 | $100 | Implemented |
KU0297 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,367 | $0 | Not Implemented |
KU0297 # 08 Y:1989 | 08 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $581 | $350 | Implemented |
KU0297 # 07 Y:1989 | 07 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,339 | $7,000 | Not Implemented |
KU0297 # 03 Y:1989 | 03 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,843 | $3,200 | Not Implemented |
KU0297 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $218 | $119 | Implemented |
KU0297 # 05 Y:1989 | 05 | 1989 | OPTIMIZE PLANT POWER FACTOR | $7,688 | $13,500 | Implemented |