Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
61
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0353 # 07 Y:1991 | 07 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $297 | $1,000 | Implemented |
KU0353 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $1,871 | $300 | Implemented |
KU0336 # 06 Y:1991 | 06 | 1991 | REDESIGN PROCESS | $10,585 | $25,200 | Implemented |
KU0336 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $5,650 | $17,100 | Implemented |
KU0336 # 08 Y:1991 | 08 | 1991 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $1,112 | $0 | Implemented |
KU0336 # 09 Y:1991 | 09 | 1991 | INSTALL SET-BACK TIMERS | $899 | $1,000 | Implemented |
KU0336 # 10 Y:1991 | 10 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $366 | $0 | Implemented |
KU0336 # 11 Y:1991 | 11 | 1991 | RECOVER AND REUSE COOLING WATER | $9,720 | $5,340 | Implemented |
KU0336 # 04 Y:1991 | 04 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,818 | $3,800 | Implemented |
KU0336 # 03 Y:1991 | 03 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,114 | $27,600 | Implemented |
KU0336 # 02 Y:1991 | 02 | 1991 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $15,055 | $18,000 | Implemented |
KU0336 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,491 | $19,500 | Implemented |
KU0336 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $22,099 | $22,000 | Implemented |
KU0334 # 07 Y:1991 | 07 | 1991 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $10,665 | $22,600 | Implemented |
KU0334 # 01 Y:1991 | 01 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $10,153 | $1,800 | Implemented |
KU0334 # 02 Y:1991 | 02 | 1991 | SCHEDULE USE OF ELEVATORS TO CONSERVE ENERGY | $336 | $40 | Implemented |
KU0334 # 03 Y:1991 | 03 | 1991 | USE COLD WASTE WATER TO COOL CHILLER FEED WATER | $22,062 | $33,150 | Implemented |
KU0334 # 04 Y:1991 | 04 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,034 | $4,200 | Implemented |
KU0334 # 05 Y:1991 | 05 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,382 | $0 | Implemented |
KU0334 # 06 Y:1991 | 06 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,054 | $16,950 | Implemented |
KU0334 # 08 Y:1991 | 08 | 1991 | INSTALL SET-BACK TIMERS | $454 | $120 | Implemented |
KU0333 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $85 | $84 | Implemented |
KU0333 # 07 Y:1991 | 07 | 1991 | INSTALL SET-BACK TIMERS | $698 | $1,000 | Implemented |
KU0333 # 06 Y:1991 | 06 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,398 | $200 | Implemented |
KU0333 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $153 | $0 | Implemented |