Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
951
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0210 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $104,709 | $19,500 | Implemented |
LL0210 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,408 | $9,920 | Implemented |
LL0210 # 03 Y:2004 | 03 | 2004 | BURN A LESS EXPENSIVE GRADE OF FUEL | $5,147 | $1,528 | Implemented |
LL0210 # 06 Y:2004 | 06 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $687 | $270 | Implemented |
LL0210 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $208 | $240 | Implemented |
LL0210 # 08 Y:2004 | 08 | 2004 | USE PHOTOCELL CONTROLS | $133 | $90 | Implemented |
LL0209 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $107,401 | $19,500 | Implemented |
LL0209 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,303 | $12,640 | Implemented |
LL0209 # 03 Y:2004 | 03 | 2004 | USE PHOTOCELL CONTROLS | $8,552 | $882 | Implemented |
LL0209 # 04 Y:2004 | 04 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,124 | $30 | Implemented |
LL0209 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,679 | $489 | Implemented |
LL0209 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $1,024 | $1,080 | Implemented |
LL0205 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,430 | $1,080 | Implemented |
LL0205 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,750 | $1,820 | Implemented |
LL0206 # 01 Y:2004 | 01 | 2004 | INSULATE BARE EQUIPMENT | $28,231 | $3,647 | Implemented |
LL0206 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,510 | $8,280 | Implemented |
LL0206 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,379 | $30 | Implemented |
LL0206 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $620 | $525 | Implemented |
LL0206 # 07 Y:2004 | 07 | 2004 | USE PHOTOCELL CONTROLS | $323 | $90 | Implemented |
LL0206 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $160 | $150 | Implemented |
LL0206 # 09 Y:2004 | 09 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $181 | $150 | Implemented |
LL0206 # 10 Y:2004 | 10 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $114,500 | $4,820 | Implemented |
LL0206 # 11 Y:2004 | 11 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,830 | $1,790 | Implemented |
LL0204 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,973 | $20,331 | Implemented |
LL0204 # 02 Y:2004 | 02 | 2004 | INSTALL OCCUPANCY SENSORS | $6,514 | $360 | Implemented |