Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,055
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0131 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $213 | $81 | Not Implemented |
LL0131 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $159 | $0 | Not Implemented |
LL0130 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,705 | $0 | Implemented |
LL0130 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,729 | $2,340 | Implemented |
LL0130 # 03 Y:2002 | 03 | 2002 | INSTALL SKYLIGHTS | $6,716 | $734 | Not Implemented |
LL0130 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,838 | $0 | Implemented |
LL0130 # 05 Y:2002 | 05 | 2002 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,728 | $621 | Implemented |
LL0130 # 06 Y:2002 | 06 | 2002 | USE PHOTOCELL CONTROLS | $680 | $230 | Not Implemented |
LL0130 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $600 | $0 | Implemented |
LL0130 # 08 Y:2002 | 08 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $45,027 | $0 | Implemented |
LL0129 # 01 Y:2002 | 01 | 2002 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $191,600 | $22,000 | Implemented |
LL0129 # 02 Y:2002 | 02 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $182,915 | $7,125 | Not Implemented |
LL0129 # 03 Y:2002 | 03 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $145,921 | $7,125 | Not Implemented |
LL0129 # 04 Y:2002 | 04 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $134,101 | $7,125 | Not Implemented |
LL0129 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $121,713 | $95,025 | Implemented |
LL0129 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $29,381 | $28,907 | Implemented |
LL0129 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $52,853 | $12,720 | Implemented |
LL0129 # 08 Y:2002 | 08 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $36,741 | $7,200 | Implemented |
LL0129 # 09 Y:2002 | 09 | 2002 | USE PHOTOCELL CONTROLS | $2,065 | $702 | Not Implemented |
LL0128 # 01 Y:2002 | 01 | 2002 | CONVERT TO OXYFUEL BURNERS | $235,855 | $281,796 | Implemented |
LL0128 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,887 | $93,094 | Implemented |
LL0128 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $32,031 | $38,570 | Not Implemented |
LL0128 # 04 Y:2002 | 04 | 2002 | USE PHOTOCELL CONTROLS | $251 | $128 | Not Implemented |
LL0128 # 05 Y:2002 | 05 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,123 | $0 | Implemented |
LL0127 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $36,202 | $24,480 | Not Implemented |