Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
936
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0050 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $937 | $2,580 | Not Implemented |
LM0050 # 09 Y:2003 | 09 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $19,825 | $6,026 | Implemented |
LM0050 # 10 Y:2003 | 10 | 2003 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $5,943 | $1,000 | Implemented |
LM0050 # 11 Y:2003 | 11 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $57,825 | $12,920 | Not Implemented |
LM0050 # 12 Y:2003 | 12 | 2003 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $25,000 | $15,404 | Not Implemented |
LM0050 # 13 Y:2003 | 13 | 2003 | INSTALL AUTOMATIC PACKING EQUIPMENT | $62,400 | $100,000 | Not Implemented |
LM0050 # 14 Y:2003 | 14 | 2003 | USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY | $101,616 | $150,000 | Not Implemented |
LM0049 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $584 | $767 | Not Implemented |
LM0049 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,644 | $500 | Not Implemented |
LM0049 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,526 | $0 | Not Implemented |
LM0049 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,935 | $2,250 | Not Implemented |
LM0049 # 05 Y:2003 | 05 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,728 | $1,000 | Not Implemented |
LM0049 # 06 Y:2003 | 06 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $198,375 | $32,670 | Not Implemented |
LM0049 # 07 Y:2003 | 07 | 2003 | ADVERTISE PRODUCT OR SERVICE | $242,800 | $2,000 | Not Implemented |
LM0049 # 08 Y:2003 | 08 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $120,000 | $7,997 | Not Implemented |
LM0046 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $232 | $20 | Not Implemented |
LM0046 # 02 Y:2003 | 02 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,316 | $1,380 | Implemented |
LM0046 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,794 | $516 | Implemented |
LM0046 # 04 Y:2003 | 04 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,296 | $792 | Implemented |
LM0046 # 05 Y:2003 | 05 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $13,658 | $360 | Not Implemented |
LM0046 # 06 Y:2003 | 06 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,314 | $0 | Implemented |
LM0046 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $2,760 | $521 | Implemented |
LM0046 # 08 Y:2003 | 08 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,802 | $17,200 | Not Implemented |
LM0046 # 09 Y:2003 | 09 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $17,717 | $120 | Not Implemented |
LM0046 # 10 Y:2003 | 10 | 2003 | RECOVER AND REUSE COOLING WATER | $40,647 | $5,000 | Implemented |