Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
936
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0046 # 11 Y:2003 | 11 | 2003 | UTILIZE OUTSIDE CONTRACTING | $56,838 | $11,800 | Not Implemented |
LM0046 # 12 Y:2003 | 12 | 2003 | UTILIZE OUTSIDE CONTRACTING | $234,229 | $100,000 | Not Implemented |
LM0046 # 13 Y:2003 | 13 | 2003 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $230,000 | $336,269 | Implemented |
LM0048 # 01 Y:2003 | 01 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,065 | $0 | Not Implemented |
LM0048 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,111 | $4,650 | Implemented |
LM0048 # 03 Y:2003 | 03 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,650 | $951 | Implemented |
LM0048 # 04 Y:2003 | 04 | 2003 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,317 | $3,200 | Implemented |
LM0048 # 05 Y:2003 | 05 | 2003 | RECOVER AND REUSE COOLING WATER | $16,200 | $1,000 | Implemented |
LM0048 # 06 Y:2003 | 06 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $36,400 | $14,567 | Implemented |
LM0048 # 07 Y:2003 | 07 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $25,093 | $15,842 | Implemented |
LM0048 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $105,000 | $40,872 | Not Implemented |
LM0048 # 09 Y:2003 | 09 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $672,000 | $100,000 | Implemented |
LM0048 # 10 Y:2003 | 10 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $82,232 | $25,000 | Implemented |
LM0048 # 11 Y:2003 | 11 | 2003 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $1,700 | $2,300 | Not Implemented |
LM0048 # 12 Y:2003 | 12 | 2003 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $351 | $0 | Implemented |
LM0047 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,457 | $6,432 | Not Implemented |
LM0047 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,703 | $200 | Implemented |
LM0047 # 03 Y:2003 | 03 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $997 | $228 | Implemented |
LM0047 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $370 | $525 | Implemented |
LM0047 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $837 | $1,365 | Not Implemented |
LM0047 # 06 Y:2003 | 06 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,158 | $1,222 | Not Implemented |
LM0047 # 07 Y:2003 | 07 | 2003 | DEVELOP STANDARD OPERATING PROCEDURES | $250,000 | $26,500 | Implemented |
LM0047 # 08 Y:2003 | 08 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $138,235 | $2,000 | Implemented |
LM0047 # 09 Y:2003 | 09 | 2003 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $31,500 | $2,000 | Implemented |
LM0047 # 10 Y:2003 | 10 | 2003 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $63,000 | $5,000 | Implemented |