IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,692

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0397 # 01 Y:1997 01 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,044 $600 Implemented
MA0397 # 02 Y:1997 02 1997 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $3,025 $200 Implemented
MA0397 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,200 $0 Implemented
MA0397 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $874 $681 Not Implemented
MA0397 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $790 $404 Implemented
MA0397 # 06 Y:1997 06 1997 ADD AREA LIGHTING SWITCHES $413 $60 Not Implemented
MA0397 # 07 Y:1997 07 1997 PAY BILLS ON TIME TO AVOID LATE FEES $433 $0 Implemented
MA0396 # 01 Y:1997 01 1997 USE MAGNETIC TECHNOLOGY TO TREAT WATER $7,580 $9,347 Not Implemented
MA0396 # 02 Y:1997 02 1997 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $5,492 $11,700 Implemented
MA0396 # 03 Y:1997 03 1997 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $4,207 $14,329 Not Implemented
MA0396 # 04 Y:1997 04 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,606 $75 Implemented
MA0396 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $1,409 $60 Implemented
MA0396 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $819 $102 Not Implemented
MA0396 # 07 Y:1997 07 1997 TURN OFF EQUIPMENT WHEN NOT IN USE $182 $132 Not Implemented
MA0395 # 01 Y:1997 01 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $8,941 $16,900 Not Implemented
MA0395 # 02 Y:1997 02 1997 BURN A LESS EXPENSIVE GRADE OF FUEL $440 $0 Not Implemented
MA0395 # 03 Y:1997 03 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $20 $0 Implemented
MA0395 # 04 Y:1997 04 1997 PAY BILLS ON TIME TO AVOID LATE FEES $1,153 $0 Implemented
MA0395 # 05 Y:1997 05 1997 INSTALL OCCUPANCY SENSORS $888 $992 Implemented
MA0395 # 06 Y:1997 06 1997 USE MAGNETIC TECHNOLOGY TO TREAT WATER $825 $5,200 Not Implemented
MA0394 # 01 Y:1997 01 1997 CLEAR AND RENT EXISTING SPACE $262,500 $0 Implemented
MA0394 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $89,097 $320,340 Implemented
MA0394 # 03 Y:1997 03 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,317 $24,908 Not Implemented
MA0394 # 04 Y:1997 04 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,246 $4,225 Not Implemented
MA0394 # 05 Y:1997 05 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,330 $271 Implemented