IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,209

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0346 # 05 Y:1995 05 1995 USE MINIMUM STEAM OPERATING PRESSURE $552 $1,160 Not Implemented
MA0346 # 06 Y:1995 06 1995 CLOSE OFF UNNEEDED STEAM LINES $333 $0 Not Implemented
MA0346 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $304 $700 Not Implemented
MA0346 # 08 Y:1995 08 1995 REDUCE SCRAP PRODUCTION $40,068 $56,350 Not Implemented
MA0346 # 09 Y:1995 09 1995 RECOVER METALS FROM SPENT SOLUTIONS AND RECYCLE $14,227 $25,000 Not Implemented
MA0346 # 01 Y:1995 01 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $17,905 $100,000 Not Implemented
MA0346 # 02 Y:1995 02 1995 INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) $7,124 $30,000 Not Implemented
MA0346 # 03 Y:1995 03 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,744 $810 Not Implemented
MA0343 # 01 Y:1995 01 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $26,616 $37,300 Not Implemented
MA0343 # 02 Y:1995 02 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,446 $9,000 Not Implemented
MA0343 # 03 Y:1995 03 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,559 $3,300 Not Implemented
MA0343 # 04 Y:1995 04 1995 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $2,131 $1,750 Not Implemented
MA0343 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,114 $6,330 Implemented
MA0343 # 06 Y:1995 06 1995 COVER OPEN TANKS $828 $274 Implemented
MA0340 # 01 Y:1995 01 1995 USE POWER DURING OFF-PEAK PERIODS $4,800 $0 Implemented
MA0340 # 02 Y:1995 02 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,349 $200 Implemented
MA0340 # 03 Y:1995 03 1995 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,634 $5,995 Not Implemented
MA0340 # 04 Y:1995 04 1995 PAY UTILITY BILLS ON TIME $1,820 $0 Implemented
MA0340 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,369 $2,464 Implemented
MA0340 # 06 Y:1995 06 1995 REDUCE VENTILATION AIR $1,190 $3,320 Implemented
MA0340 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $753 $0 Implemented
MA0340 # 08 Y:1995 08 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $612 $330 Implemented
MA0340 # 09 Y:1995 09 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $558 $127 Not Implemented
MA0340 # 10 Y:1995 10 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $356 $570 Implemented
MA0339 # 01 Y:1995 01 1995 BURN A LESS EXPENSIVE GRADE OF FUEL $4,128 $1,860 Implemented