Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,929
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0584 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,098 | $9,400 | Not Implemented |
MA0580 # 01 Y:2005 | 01 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,175 | $6,831 | Not Implemented |
MA0580 # 02 Y:2005 | 02 | 2005 | USE MINIMUM SAFE OVEN VENTILATION | $8,663 | $10,750 | Not Implemented |
MA0580 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,371 | $34,720 | Implemented |
MA0580 # 04 Y:2005 | 04 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,798 | $1,375 | Implemented |
MA0580 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,905 | $0 | Implemented |
MA0580 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,479 | $825 | Not Implemented |
MA0580 # 07 Y:2005 | 07 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $611 | $0 | Not Implemented |
MA0580 # 08 Y:2005 | 08 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $444 | $0 | Not Implemented |
MA0580 # 09 Y:2005 | 09 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $312 | $0 | Not Implemented |
MA0577 # 01 Y:2005 | 01 | 2005 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $75,813 | $205,500 | Implemented |
MA0577 # 02 Y:2005 | 02 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $52,930 | $50,000 | Implemented |
MA0577 # 03 Y:2005 | 03 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $46,138 | $58,000 | Implemented |
MA0577 # 04 Y:2005 | 04 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $28,600 | $980 | Implemented |
MA0577 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,371 | $300 | Implemented |
MA0577 # 06 Y:2005 | 06 | 2005 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $6,784 | $40,425 | Implemented |
MA0574 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $179,823 | $140,865 | Implemented |
MA0574 # 02 Y:2005 | 02 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $140,952 | $230,000 | Implemented |
MA0574 # 03 Y:2005 | 03 | 2005 | BURN A LESS EXPENSIVE GRADE OF FUEL | $349,295 | $54,400 | Not Implemented |
MA0574 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $20,725 | $20,215 | Not Implemented |
MA0574 # 05 Y:2005 | 05 | 2005 | INSULATE BARE EQUIPMENT | $3,466 | $1,801 | Implemented |
MA0574 # 06 Y:2005 | 06 | 2005 | INSULATE BARE EQUIPMENT | $2,911 | $5,770 | Implemented |
MA0574 # 07 Y:2005 | 07 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $960 | $0 | Implemented |
MA0573 # 01 Y:2005 | 01 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $15,507 | $6,435 | Implemented |
MA0573 # 02 Y:2005 | 02 | 2005 | REPLACE BOILER | $5,500 | $15,900 | Not Implemented |