Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,209
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0722 # 10 Y:2014 | 10 | 2014 | INSTALL OCCUPANCY SENSORS | $599 | $1,600 | Not Implemented |
MA0722 # 09 Y:2014 | 09 | 2014 | PAY UTILITY BILLS ON TIME | $949 | $500 | Not Implemented |
MA0722 # 08 Y:2014 | 08 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $998 | $200 | Implemented |
MA0722 # 07 Y:2014 | 07 | 2014 | REDUCE VENTILATION AIR | $1,630 | $3,750 | Not Implemented |
MA0722 # 06 Y:2014 | 06 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,742 | $1,450 | Not Implemented |
MA0722 # 05 Y:2014 | 05 | 2014 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,818 | $2,750 | Not Implemented |
MA0722 # 04 Y:2014 | 04 | 2014 | REDUCE VENTILATION AIR | $2,443 | $3,000 | Not Implemented |
MA0722 # 03 Y:2014 | 03 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,147 | $9,900 | Not Implemented |
MA0722 # 02 Y:2014 | 02 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $10,940 | $1,500 | Not Implemented |
MA0722 # 01 Y:2014 | 01 | 2014 | USE POWER DURING OFF-PEAK PERIODS | $11,298 | $500 | Implemented |
MA0721 # 08 Y:2013 | 08 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,106 | $6,390 | Not Implemented |
MA0721 # 01 Y:2013 | 01 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,477 | $1,400 | Not Implemented |
MA0721 # 02 Y:2013 | 02 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,906 | $7,500 | Implemented |
MA0721 # 03 Y:2013 | 03 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,493 | $11,000 | Implemented |
MA0721 # 04 Y:2013 | 04 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,864 | $200 | Implemented |
MA0721 # 06 Y:2013 | 06 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $2,358 | $1,120 | Implemented |
MA0721 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,130 | $1,020 | Implemented |
MA0721 # 05 Y:2013 | 05 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,474 | $200 | Implemented |
MA0721 # 09 Y:2013 | 09 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,465 | $1,650 | Not Implemented |
MA0720 # 04 Y:2013 | 04 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,238 | $10,000 | Implemented |
MA0720 # 05 Y:2013 | 05 | 2013 | REDUCE VENTILATION AIR | $7,186 | $2,510 | Not Implemented |
MA0720 # 08 Y:2013 | 08 | 2013 | REDUCE VENTILATION AIR | $2,479 | $6,235 | Not Implemented |
MA0720 # 02 Y:2013 | 02 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $10,748 | $1,000 | Implemented |
MA0720 # 06 Y:2013 | 06 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,682 | $500 | Not Implemented |
MA0720 # 07 Y:2013 | 07 | 2013 | REDUCE VENTILATION AIR | $4,116 | $2,500 | Implemented |