IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,209

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0722 # 10 Y:2014 10 2014 INSTALL OCCUPANCY SENSORS $599 $1,600 Not Implemented
MA0722 # 09 Y:2014 09 2014 PAY UTILITY BILLS ON TIME $949 $500 Not Implemented
MA0722 # 08 Y:2014 08 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $998 $200 Implemented
MA0722 # 07 Y:2014 07 2014 REDUCE VENTILATION AIR $1,630 $3,750 Not Implemented
MA0722 # 06 Y:2014 06 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $1,742 $1,450 Not Implemented
MA0722 # 05 Y:2014 05 2014 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $1,818 $2,750 Not Implemented
MA0722 # 04 Y:2014 04 2014 REDUCE VENTILATION AIR $2,443 $3,000 Not Implemented
MA0722 # 03 Y:2014 03 2014 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,147 $9,900 Not Implemented
MA0722 # 02 Y:2014 02 2014 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $10,940 $1,500 Not Implemented
MA0722 # 01 Y:2014 01 2014 USE POWER DURING OFF-PEAK PERIODS $11,298 $500 Implemented
MA0721 # 08 Y:2013 08 2013 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,106 $6,390 Not Implemented
MA0721 # 01 Y:2013 01 2013 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $15,477 $1,400 Not Implemented
MA0721 # 02 Y:2013 02 2013 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $10,906 $7,500 Implemented
MA0721 # 03 Y:2013 03 2013 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,493 $11,000 Implemented
MA0721 # 04 Y:2013 04 2013 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $4,864 $200 Implemented
MA0721 # 06 Y:2013 06 2013 REPAIR AND ELIMINATE STEAM LEAKS $2,358 $1,120 Implemented
MA0721 # 07 Y:2013 07 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,130 $1,020 Implemented
MA0721 # 05 Y:2013 05 2013 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,474 $200 Implemented
MA0721 # 09 Y:2013 09 2013 INSTALL / REPAIR INSULATION ON STEAM LINES $1,465 $1,650 Not Implemented
MA0720 # 04 Y:2013 04 2013 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,238 $10,000 Implemented
MA0720 # 05 Y:2013 05 2013 REDUCE VENTILATION AIR $7,186 $2,510 Not Implemented
MA0720 # 08 Y:2013 08 2013 REDUCE VENTILATION AIR $2,479 $6,235 Not Implemented
MA0720 # 02 Y:2013 02 2013 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $10,748 $1,000 Implemented
MA0720 # 06 Y:2013 06 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $5,682 $500 Not Implemented
MA0720 # 07 Y:2013 07 2013 REDUCE VENTILATION AIR $4,116 $2,500 Implemented