Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,692
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0633 # 03 Y:2008 | 03 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $857 | $300 | Not Implemented |
MA0633 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,171 | $0 | Not Implemented |
MA0635 # 01 Y:2008 | 01 | 2008 | USE MINIMUM SAFE OVEN VENTILATION | $17,227 | $51,900 | Implemented |
MA0635 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,508 | $40,166 | Not Implemented |
MA0635 # 03 Y:2008 | 03 | 2008 | REDUCE VENTILATION AIR | $21,303 | $8,200 | Implemented |
MA0635 # 04 Y:2008 | 04 | 2008 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $18,922 | $4,000 | Implemented |
MA0635 # 05 Y:2008 | 05 | 2008 | BURN A LESS EXPENSIVE GRADE OF FUEL | $16,990 | $27,590 | Implemented |
MA0635 # 06 Y:2008 | 06 | 2008 | COVER OPEN TANKS | $13,756 | $53,000 | Implemented |
MA0635 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,446 | $3,288 | Implemented |
MA0635 # 08 Y:2008 | 08 | 2008 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,508 | $12,000 | Not Implemented |
MA0635 # 09 Y:2008 | 09 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,255 | $5,700 | Not Implemented |
MA0635 # 10 Y:2008 | 10 | 2008 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,859 | $1,200 | Not Implemented |
MA0635 # 11 Y:2008 | 11 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,035 | $1,600 | Not Implemented |
MA0635 # 12 Y:2008 | 12 | 2008 | USE MINIMUM SAFE OVEN VENTILATION | $880 | $500 | Implemented |
MA0634 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $33,014 | $119,495 | Implemented |
MA0634 # 02 Y:2008 | 02 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $11,407 | $20,000 | Not Implemented |
MA0634 # 03 Y:2008 | 03 | 2008 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,058 | $3,000 | Not Implemented |
MA0634 # 04 Y:2008 | 04 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,932 | $2,500 | Implemented |
MA0634 # 05 Y:2008 | 05 | 2008 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,034 | $6,000 | Not Implemented |
MA0634 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $498 | $500 | Implemented |
MA0632 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,404 | $14,500 | Implemented |
MA0632 # 02 Y:2008 | 02 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,185 | $17,080 | Not Implemented |
MA0632 # 03 Y:2008 | 03 | 2008 | AIR CONDITION ONLY SPACE NECESSARY | $4,818 | $19,300 | Not Implemented |
MA0632 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,265 | $4,100 | Implemented |
MA0632 # 05 Y:2008 | 05 | 2008 | REDUCE VENTILATION AIR | $2,499 | $9,000 | Implemented |