IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,886

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0094 # 02 Y:2004 02 2004 REDUCE DEFECTS BY REDUCING PRODUCT TIPPING $95,473 $150 Implemented
MI0094 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $-177 $590 Implemented
MI0094 # 04 Y:2004 04 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $9,418 $92 Implemented
MI0094 # 07 Y:2004 07 2004 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $11,093 $2,056 Implemented
MI0094 # 08 Y:2004 08 2004 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS $69,699 $5,966 Implemented
MI0094 # 09 Y:2004 09 2004 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $47,623 $4,110 Implemented
MI0093 # 07 Y:2004 07 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $8,755 $510 Implemented
MI0093 # 08 Y:2004 08 2004 INSTALL ROTATING CAROUSELS TO REDUCE SET-UP TIMES $23,333 $21,000 Implemented
MI0092 # 02 Y:2004 02 2004 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $21,190 $50,000 Implemented
MI0092 # 06 Y:2004 06 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,031 $1,350 Implemented
MI0091 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $19,034 $35,520 Implemented
MI0091 # 04 Y:2004 04 2004 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $26,520 $1,000 Implemented
MI0089 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $22,325 $2,300 Implemented
MI0089 # 04 Y:2004 04 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,010 $590 Implemented
MI0089 # 05 Y:2004 05 2004 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $25,036 $50 Implemented
MI0089 # 06 Y:2004 06 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,772 $25,286 Implemented
MI0088 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $28,772 $2,300 Implemented
MI0088 # 03 Y:2004 03 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $-1,117 $750 Implemented
MI0088 # 04 Y:2004 04 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $22,760 $40,140 Implemented
MI0088 # 05 Y:2004 05 2004 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $427,935 $0 Implemented
MI0088 # 08 Y:2004 08 2004 PAY BILLS ON TIME TO AVOID LATE FEES $770 $0 Implemented
MI0086 # 01 Y:2004 01 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $21,915 $2,300 Implemented
MI0086 # 02 Y:2004 02 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $3,200 $2,300 Implemented
MI0086 # 03 Y:2004 03 2004 AIR CONDITION ONLY SPACE NECESSARY $792 $80 Implemented
MI0086 # 04 Y:2004 04 2004 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $90,000 $50,000 Implemented