Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,050
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0013 # 07 Y:2001 | 07 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,791 | $15 | Not Implemented |
MI0012 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $656 | $260 | Implemented |
MI0012 # 02 Y:2001 | 02 | 2001 | UTILIZE JOB COSTING SOFTWARE | $58,500 | $12,000 | Implemented |
MI0012 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,550 | $306 | Implemented |
MI0012 # 04 Y:2001 | 04 | 2001 | CONDENSE OPERATION INTO ONE BUILDING | $5,315 | $2,040 | Implemented |
MI0012 # 05 Y:2001 | 05 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,188 | $5,000 | Implemented |
MI0012 # 06 Y:2001 | 06 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,190 | $29 | Implemented |
MI0011 # 01 Y:2001 | 01 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $59,040 | $5,100 | Implemented |
MI0011 # 02 Y:2001 | 02 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $73,364 | $5,100 | Implemented |
MI0011 # 03 Y:2001 | 03 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $18,892 | $5,100 | Implemented |
MI0011 # 04 Y:2001 | 04 | 2001 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $114,007 | $5,100 | Implemented |
MI0011 # 05 Y:2001 | 05 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $316,160 | $164,000 | Implemented |
MI0011 # 06 Y:2001 | 06 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,793 | $19 | Implemented |
MI0011 # 07 Y:2001 | 07 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $10,662 | $760 | Not Implemented |
MI0010 # 01 Y:2001 | 01 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $2,160 | $1,009 | Implemented |
MI0010 # 02 Y:2001 | 02 | 2001 | METER WASTE WATER | $3,711 | $3,650 | Implemented |
MI0010 # 03 Y:2001 | 03 | 2001 | IMPROVE SPACE COMFORT CONDITIONING | $47,345 | $7,000 | Implemented |
MI0010 # 04 Y:2001 | 04 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,000 | $5,000 | Implemented |
MI0010 # 05 Y:2001 | 05 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,511 | $6,500 | Not Implemented |
MI0009 # 01 Y:2001 | 01 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $14,580 | $5,000 | Not Implemented |
MI0009 # 02 Y:2001 | 02 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,327 | $12 | Not Implemented |
MI0009 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,745 | $12 | Not Implemented |
MI0009 # 04 Y:2001 | 04 | 2001 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $43,740 | $2,550 | Not Implemented |
MI0009 # 05 Y:2001 | 05 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $10,083 | $1,102 | Not Implemented |
MI0007 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,671 | $281 | Implemented |