Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,083

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0447 # 05 Y:2024 05 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,840 $3,750 Implemented
MI0447 # 06 Y:2024 06 2024 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $792 $320 Implemented
MI0446 # 03 Y:2024 03 2024 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $15,109 $12,480 n/a
MI0446 # 02 Y:2024 02 2024 UPGRADE CONVEYORS $36,000 $40,966 n/a
MI0446 # 01 Y:2024 01 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $103,738 $390,000 n/a
MI0444 # 10 Y:2024 10 2024 INSTALL OCCUPANCY SENSORS $485 $903 Not Implemented
MI0444 # 09 Y:2024 09 2024 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $717 $2,430 Not Implemented
MI0444 # 08 Y:2024 08 2024 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $729 $34 Not Implemented
MI0444 # 07 Y:2024 07 2024 MINIMIZE WATER USAGE $1,521 $800 Implemented
MI0444 # 06 Y:2024 06 2024 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,309 $5,731 Not Implemented
MI0444 # 05 Y:2024 05 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,005 $9,012 Not Implemented
MI0444 # 04 Y:2024 04 2024 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE $5,488 $965 Not Implemented
MI0444 # 03 Y:2024 03 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,757 $1,980 Implemented
MI0444 # 02 Y:2024 02 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,226 $1,016 Implemented
MI0444 # 01 Y:2024 01 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $12,690 $26,240 Not Implemented
MI0443 # 01 Y:2024 01 2024 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $18,913 $0 Not Implemented
MI0443 # 02 Y:2024 02 2024 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $14,162 $54,938 Implemented
MI0443 # 03 Y:2024 03 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,706 $1,980 Not Implemented
MI0443 # 04 Y:2024 04 2024 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $7,616 $18,760 Not Implemented
MI0443 # 06 Y:2024 06 2024 USE SOLAR HEAT TO HEAT WATER $4,071 $12,390 Not Implemented
MI0443 # 05 Y:2024 05 2024 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $6,571 $14,916 Implemented
MI0443 # 08 Y:2024 08 2024 INSTALL OCCUPANCY SENSORS $1,287 $501 Implemented
MI0443 # 07 Y:2024 07 2024 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $3,482 $240 Implemented
MI0442 # 03 Y:2024 03 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,876 $16,028 Not Implemented
MI0442 # 04 Y:2024 04 2024 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $9,720 $159,280 Not Implemented