Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

169

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MS0160 # 08 Y:2000 08 2000 COMBINE UTILITY METERS $3,023 $1,000 Not Implemented
MS0160 # 09 Y:2000 09 2000 BURN WASTE OIL FOR HEAT $1,949 $2,067 Not Implemented
MS0129 # 01 Y:1999 01 1999 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $11,582 $0 Not Implemented
MS0129 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,133 $479 Not Implemented
MS0129 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,721 $29,711 Not Implemented
MS0129 # 04 Y:1999 04 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $1,500 $3,600 Not Implemented
MS0129 # 05 Y:1999 05 1999 BURN WASTE OIL FOR HEAT $623 $1,804 Not Implemented
MS0129 # 06 Y:1999 06 1999 ELIMINATE LEAKS IN WATER LINES AND VALVES $3,555 $250 Implemented
MS0129 # 07 Y:1999 07 1999 $6,831 $7,225 Not Implemented
MS0128 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $441 $94 Implemented
MS0128 # 02 Y:1999 02 1999 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,291 $149 Implemented
MS0128 # 03 Y:1999 03 1999 INSTALL TIMERS AND/OR THERMOSTATS $905 $472 Implemented
MS0128 # 04 Y:1999 04 1999 USE RE-USABLE FILTERS $143 $160 Implemented
MS0119 # 01 Y:1998 01 1998 USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY $24,225 $7,315 Not Implemented
MS0119 # 02 Y:1998 02 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $10,424 $21,311 Not Implemented
MS0119 # 03 Y:1998 03 1998 USE SYNTHETIC LUBRICANT $1,266 $440 Implemented
MS0119 # 04 Y:1998 04 1998 USE DEMAND CONTROLLER OR LOAD SHEDDER $32,240 $31,500 Implemented
MS0119 # 05 Y:1998 05 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $109,983 $0 Implemented
MS0119 # 06 Y:1998 06 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $12,511 $10,368 Not Implemented
MS0119 # 07 Y:1998 07 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $12,580 $31,767 Not Implemented
MS0119 # 08 Y:1998 08 1998 BURN WASTE OIL FOR HEAT $26,282 $24,283 Not Implemented
MS0119 # 09 Y:1998 09 1998 $8,100 $5,729 Not Implemented
MS0119 # 10 Y:1998 10 1998 $110,250 $31,460 Implemented
MS0109 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,140 $3,776 Implemented
MS0109 # 02 Y:1998 02 1998 INSTALL TIMERS AND/OR THERMOSTATS $402 $232 Implemented