Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,391
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0440 # 02 Y:2011 | 02 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $15,127 | $20,158 | Implemented |
NC0440 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,025 | $500 | Implemented |
NC0440 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,312 | $8,420 | Implemented |
NC0435 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,479 | $72,211 | Implemented |
NC0435 # 03 Y:2011 | 03 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,887 | $7,760 | Implemented |
NC0435 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $661 | $1,911 | Implemented |
NC0435 # 06 Y:2011 | 06 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $295 | $1,500 | Implemented |
NC0436 # 03 Y:2011 | 03 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $18,076 | $4,000 | Implemented |
NC0436 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,560 | $100 | Implemented |
NC0436 # 06 Y:2011 | 06 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,954 | $6,435 | Implemented |
NC0436 # 08 Y:2011 | 08 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,009 | $1,000 | Implemented |
NC0439 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,669 | $39,646 | Implemented |
NC0439 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $330 | $106 | Implemented |
NC0439 # 04 Y:2011 | 04 | 2011 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,390 | $4,200 | Implemented |
NC0439 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $4,934 | $2,393 | Implemented |
NC0439 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,953 | $100 | Implemented |
NC0434 # 01 Y:2011 | 01 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,138 | $2,127 | Implemented |
NC0434 # 02 Y:2011 | 02 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,152 | $14,895 | Implemented |
NC0434 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,424 | $1,000 | Implemented |
NC0434 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $142 | $100 | Implemented |
NC0434 # 06 Y:2011 | 06 | 2011 | COVER OPEN TANKS | $414 | $908 | Implemented |
NC0434 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,609 | $32,453 | Implemented |
NC0434 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,087 | $10,660 | Implemented |
NC0434 # 09 Y:2011 | 09 | 2011 | REPLACE ELECTRIC MOTOR WITH FOSSIL FUEL ENGINE | $1,039 | $876 | Implemented |
NC0433 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $81,541 | $230,949 | Implemented |