Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0357 # 03 Y:2007 | 03 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $699 | $375 | Not Implemented |
NC0357 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,527 | $4,761 | Not Implemented |
NC0357 # 05 Y:2007 | 05 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $277 | $100 | Implemented |
NC0354 # 01 Y:2007 | 01 | 2007 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $39,874 | $45,600 | Not Implemented |
NC0354 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $32,774 | $100,000 | Not Implemented |
NC0354 # 03 Y:2007 | 03 | 2007 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $65,972 | $100,000 | Not Implemented |
NC0354 # 04 Y:2007 | 04 | 2007 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $35,076 | $2,000 | Not Implemented |
NC0354 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,375 | $100 | Implemented |
NC0354 # 06 Y:2007 | 06 | 2007 | ADJUST BURNERS FOR EFFICIENT OPERATION | $7,411 | $2,000 | Implemented |
NC0354 # 07 Y:2007 | 07 | 2007 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,714 | $1,000 | Not Implemented |
NC0354 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,936 | $2,559 | Implemented |
NC0353 # 01 Y:2007 | 01 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $17,011 | $10,953 | Implemented |
NC0353 # 02 Y:2007 | 02 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $9,457 | $1,526 | Implemented |
NC0353 # 03 Y:2007 | 03 | 2007 | REPAIR AND ELIMINATE STEAM LEAKS | $3,562 | $3,000 | Implemented |
NC0353 # 04 Y:2007 | 04 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,308 | $2,000 | Implemented |
NC0353 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $654 | $100 | Implemented |
NC0353 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,078 | $20,770 | Implemented |
NC0353 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,055 | $712 | Implemented |
NC0352 # 01 Y:2007 | 01 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $28,336 | $8,000 | Implemented |
NC0352 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,199 | $1,371 | Not Implemented |
NC0352 # 03 Y:2007 | 03 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,127 | $50 | Implemented |
NC0352 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $784 | $1,000 | Implemented |
NC0352 # 05 Y:2007 | 05 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,565 | $4,000 | Not Implemented |
NC0352 # 06 Y:2007 | 06 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $721 | $100 | Implemented |
NC0355 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $362,261 | $136,000 | Not Implemented |