Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,985
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0184 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $685 | $600 | Implemented |
NC0184 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $163 | $240 | Implemented |
NC0187 # 01 Y:2000 | 01 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,836 | $1,000 | Not Implemented |
NC0187 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $10,033 | $5,000 | Not Implemented |
NC0187 # 03 Y:2000 | 03 | 2000 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $975 | $2,640 | Not Implemented |
NC0187 # 04 Y:2000 | 04 | 2000 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $7,128 | $20,000 | Not Implemented |
NC0187 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $689 | $1,428 | Not Implemented |
NC0187 # 06 Y:2000 | 06 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,072 | $24,000 | Not Implemented |
NC0187 # 07 Y:2000 | 07 | 2000 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $3,506 | $5,416 | Not Implemented |
NC0187 # 08 Y:2000 | 08 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $75 | $260 | Not Implemented |
NC0187 # 09 Y:2000 | 09 | 2000 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $8,686 | $25,740 | Not Implemented |
NC0183 # 01 Y:2000 | 01 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $7,429 | $2,731 | Implemented |
NC0183 # 02 Y:2000 | 02 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $6,611 | $11,000 | Implemented |
NC0183 # 03 Y:2000 | 03 | 2000 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $3,631 | $7,500 | Not Implemented |
NC0183 # 04 Y:2000 | 04 | 2000 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,091 | $3,300 | Implemented |
NC0183 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $884 | $600 | Implemented |
NC0183 # 06 Y:2000 | 06 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $4,983 | $10,750 | Not Implemented |
NC0183 # 07 Y:2000 | 07 | 2000 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $13,598 | $12,000 | Not Implemented |
NC0183 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,838 | $3,700 | Implemented |
NC0183 # 09 Y:2000 | 09 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $500 | $500 | Not Implemented |
NC0183 # 10 Y:2000 | 10 | 2000 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $20,448 | $5,000 | Implemented |
NC0182 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,121 | $3,086 | Not Implemented |
NC0182 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $357 | $375 | Not Implemented |
NC0182 # 03 Y:2000 | 03 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $632 | $167 | Not Implemented |
NC0182 # 04 Y:2000 | 04 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $579 | $420 | Implemented |