IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,176

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0278 # 06 Y:2004 06 2004 USE PHOTOCELL CONTROLS $72 $130 Implemented
NC0277 # 01 Y:2004 01 2004 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $40,000 $1,000 Not Implemented
NC0277 # 02 Y:2004 02 2004 DEVELOP A REPAIR/REPLACE POLICY $2,250 $710 Implemented
NC0277 # 03 Y:2004 03 2004 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,330 $6,680 Implemented
NC0277 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $750 $782 Implemented
NC0277 # 05 Y:2004 05 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,387 $1,900 Not Implemented
NC0277 # 06 Y:2004 06 2004 ADJUST BURNERS FOR EFFICIENT OPERATION $1,049 $1,000 Implemented
NC0276 # 01 Y:2004 01 2004 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $13,019 $18,000 Not Implemented
NC0276 # 02 Y:2004 02 2004 RECOVER WASTE HEAT FROM EQUIPMENT $14,986 $16,406 Not Implemented
NC0276 # 03 Y:2004 03 2004 $18,000 $8,050 Implemented
NC0276 # 04 Y:2004 04 2004 INSULATE BARE EQUIPMENT $14,713 $3,487 Not Implemented
NC0276 # 05 Y:2004 05 2004 DEVELOP A REPAIR/REPLACE POLICY $1,432 $1,085 Implemented
NC0276 # 06 Y:2004 06 2004 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,405 $5,000 Not Implemented
NC0276 # 07 Y:2004 07 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,023 $1,170 Implemented
NC0275 # 01 Y:2003 01 2003 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,058 $5,954 Not Implemented
NC0275 # 02 Y:2003 02 2003 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $25,721 $63,800 Not Implemented
NC0275 # 03 Y:2003 03 2003 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $12,088 $7,190 Not Implemented
NC0275 # 04 Y:2003 04 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $4,207 $4,563 Implemented
NC0275 # 05 Y:2003 05 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $455 $683 Implemented
NC0275 # 06 Y:2003 06 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,010 $4,120 Not Implemented
NC0272 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $728 $2,803 Implemented
NC0272 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,885 $610 Implemented
NC0272 # 03 Y:2003 03 2003 RECOVER AND REUSE WASTE MATERIAL $990 $400 Implemented
NC0272 # 04 Y:2003 04 2003 USE PHOTOCELL CONTROLS $167 $235 Implemented
NC0272 # 05 Y:2003 05 2003 USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING $351 $900 Not Implemented