Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0278 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $72 | $130 | Implemented |
NC0277 # 01 Y:2004 | 01 | 2004 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $40,000 | $1,000 | Not Implemented |
NC0277 # 02 Y:2004 | 02 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $2,250 | $710 | Implemented |
NC0277 # 03 Y:2004 | 03 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,330 | $6,680 | Implemented |
NC0277 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $750 | $782 | Implemented |
NC0277 # 05 Y:2004 | 05 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,387 | $1,900 | Not Implemented |
NC0277 # 06 Y:2004 | 06 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,049 | $1,000 | Implemented |
NC0276 # 01 Y:2004 | 01 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $13,019 | $18,000 | Not Implemented |
NC0276 # 02 Y:2004 | 02 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,986 | $16,406 | Not Implemented |
NC0276 # 03 Y:2004 | 03 | 2004 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $18,000 | $8,050 | Implemented |
NC0276 # 04 Y:2004 | 04 | 2004 | INSULATE BARE EQUIPMENT | $14,713 | $3,487 | Not Implemented |
NC0276 # 05 Y:2004 | 05 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $1,432 | $1,085 | Implemented |
NC0276 # 06 Y:2004 | 06 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,405 | $5,000 | Not Implemented |
NC0276 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,023 | $1,170 | Implemented |
NC0275 # 01 Y:2003 | 01 | 2003 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,058 | $5,954 | Not Implemented |
NC0275 # 02 Y:2003 | 02 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,721 | $63,800 | Not Implemented |
NC0275 # 03 Y:2003 | 03 | 2003 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $12,088 | $7,190 | Not Implemented |
NC0275 # 04 Y:2003 | 04 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,207 | $4,563 | Implemented |
NC0275 # 05 Y:2003 | 05 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $683 | Implemented |
NC0275 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,010 | $4,120 | Not Implemented |
NC0272 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $728 | $2,803 | Implemented |
NC0272 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,885 | $610 | Implemented |
NC0272 # 03 Y:2003 | 03 | 2003 | RECOVER AND REUSE WASTE MATERIAL | $990 | $400 | Implemented |
NC0272 # 04 Y:2003 | 04 | 2003 | USE PHOTOCELL CONTROLS | $167 | $235 | Implemented |
NC0272 # 05 Y:2003 | 05 | 2003 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $351 | $900 | Not Implemented |