Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0243 # 04 Y:2002 | 04 | 2002 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,543 | $6,300 | Implemented |
NC0243 # 05 Y:2002 | 05 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $4,291 | $2,500 | Implemented |
NC0243 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $200 | $125 | Not Implemented |
NC0243 # 07 Y:2002 | 07 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $682 | $351 | Not Implemented |
NC0243 # 08 Y:2002 | 08 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $820 | $1,753 | Implemented |
NC0249 # 01 Y:2002 | 01 | 2002 | KEEP EQUIPMENT CLEAN | $20,000 | $10,600 | n/a |
NC0249 # 02 Y:2002 | 02 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,557 | $0 | n/a |
NC0249 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $12,181 | $500 | n/a |
NC0249 # 04 Y:2002 | 04 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $621 | $290 | n/a |
NC0249 # 05 Y:2002 | 05 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $68 | $0 | n/a |
NC0249 # 06 Y:2002 | 06 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,159 | $2,600 | n/a |
NC0249 # 07 Y:2002 | 07 | 2002 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $658 | $0 | n/a |
NC0249 # 08 Y:2002 | 08 | 2002 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $10,000 | $10,000 | n/a |
NC0242 # 01 Y:2002 | 01 | 2002 | ADJUST BURNERS FOR EFFICIENT OPERATION | $10,271 | $1,000 | Implemented |
NC0242 # 02 Y:2002 | 02 | 2002 | FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM | $9,455 | $10,000 | Not Implemented |
NC0242 # 03 Y:2002 | 03 | 2002 | TREAT AND REUSE RINSE WATERS | $28,786 | $5,000 | Not Implemented |
NC0242 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $6,131 | $10,062 | Not Implemented |
NC0242 # 05 Y:2002 | 05 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $547 | $369 | Implemented |
NC0242 # 06 Y:2002 | 06 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $2,368 | $1,200 | Implemented |
NC0242 # 07 Y:2002 | 07 | 2002 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $5,981 | $3,100 | Implemented |
NC0241 # 01 Y:2002 | 01 | 2002 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $6,456 | $8,000 | Implemented |
NC0241 # 02 Y:2002 | 02 | 2002 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,506 | $6,000 | Not Implemented |
NC0241 # 03 Y:2002 | 03 | 2002 | DEVELOP A REPAIR/REPLACE POLICY | $4,751 | $6,493 | Implemented |
NC0241 # 04 Y:2002 | 04 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $503 | $576 | Not Implemented |
NC0241 # 05 Y:2002 | 05 | 2002 | KEEP BOILER TUBES CLEAN | $499 | $1,600 | Implemented |