Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
384
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0568 # 09 Y:2016 | 09 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,551 | $78,500 | Not Implemented |
NC0568 # 10 Y:2016 | 10 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $25,240 | $100,000 | Not Implemented |
NC0566 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $788 | $200 | Implemented |
NC0566 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $231,779 | $419,073 | Implemented |
NC0566 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,183 | $44,349 | Implemented |
NC0566 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,757 | $5,000 | Implemented |
NC0566 # 04 Y:2016 | 04 | 2016 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $52,211 | $10,000 | Not Implemented |
NC0566 # 05 Y:2016 | 05 | 2016 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $107,179 | $300,000 | Not Implemented |
NC0566 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,988 | $100 | Implemented |
NC0566 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,802 | $12,000 | Not Implemented |
NC0566 # 09 Y:2016 | 09 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $2,230 | $1,000 | Implemented |
NC0566 # 10 Y:2016 | 10 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,287 | $2,000 | Implemented |
NC0566 # 11 Y:2016 | 11 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $4,453 | $4,256 | Implemented |
NC0566 # 12 Y:2016 | 12 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,706 | $230 | Implemented |
NC0560 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $474 | $455 | Implemented |
NC0560 # 15 Y:2016 | 15 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,030 | $200 | Not Implemented |
NC0560 # 14 Y:2016 | 14 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $2,514 | $5,865 | Implemented |
NC0560 # 13 Y:2016 | 13 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,597 | $500 | Implemented |
NC0560 # 12 Y:2016 | 12 | 2016 | USE PHOTOCELL CONTROLS | $194 | $250 | Implemented |
NC0560 # 10 Y:2016 | 10 | 2016 | INSTALL OCCUPANCY SENSORS | $519 | $521 | Implemented |
NC0560 # 01 Y:2016 | 01 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $35,613 | $105,000 | Not Implemented |
NC0560 # 02 Y:2016 | 02 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $15,200 | $4,000 | Implemented |
NC0560 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,460 | $200 | Implemented |
NC0560 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $17,627 | $1,000 | Implemented |
NC0560 # 05 Y:2016 | 05 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,243 | $26,000 | Implemented |