Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
291
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0551 # 07 Y:2015 | 07 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,566 | $4,256 | Not Implemented |
NC0551 # 05 Y:2015 | 05 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,626 | $2,505 | Not Implemented |
NC0551 # 06 Y:2015 | 06 | 2015 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $509 | $900 | Not Implemented |
NC0556 # 02 Y:2015 | 02 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,806 | $5,000 | Not Implemented |
NC0556 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $578 | $868 | Implemented |
NC0556 # 04 Y:2015 | 04 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,076 | $3,200 | Not Implemented |
NC0556 # 03 Y:2015 | 03 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,438 | $12,000 | Implemented |
NC0556 # 01 Y:2015 | 01 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $59,808 | $90,000 | Implemented |
NC0556 # 05 Y:2015 | 05 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $1,836 | $4,256 | Implemented |
NC0556 # 06 Y:2015 | 06 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,228 | $200 | Not Implemented |
NC0556 # 07 Y:2015 | 07 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,584 | $8,350 | Implemented |
NC0552 # 03 Y:2015 | 03 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $49,347 | $200,000 | Not Implemented |
NC0552 # 15 Y:2015 | 15 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $16,884 | $2,813 | Not Implemented |
NC0552 # 04 Y:2015 | 04 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,541 | $30,000 | Not Implemented |
NC0552 # 07 Y:2015 | 07 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $71,338 | $65,000 | Not Implemented |
NC0552 # 02 Y:2015 | 02 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $174,643 | $100,000 | Not Implemented |
NC0552 # 09 Y:2015 | 09 | 2015 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $67,578 | $150,000 | Not Implemented |
NC0552 # 12 Y:2015 | 12 | 2015 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $165,594 | $3,000 | Implemented |
NC0552 # 10 Y:2015 | 10 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $105,601 | $192,000 | Not Implemented |
NC0552 # 05 Y:2015 | 05 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,960 | $6,000 | Not Implemented |
NC0552 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,081 | $320 | Implemented |
NC0552 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $99,030 | $1,000 | Implemented |
NC0552 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,792,252 | $500,000 | Not Implemented |
NC0552 # 08 Y:2015 | 08 | 2015 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $86,285 | $45,000 | Not Implemented |
NC0552 # 11 Y:2015 | 11 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,528 | $150 | Implemented |