Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0568 # 08 Y:2016 | 08 | 2016 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $8,890 | $25,230 | Not Implemented |
NC0568 # 09 Y:2016 | 09 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,551 | $78,500 | Not Implemented |
NC0568 # 10 Y:2016 | 10 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $25,240 | $100,000 | Not Implemented |
NC0566 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $231,779 | $419,073 | Implemented |
NC0566 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $54,183 | $44,349 | Implemented |
NC0566 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,757 | $5,000 | Implemented |
NC0566 # 04 Y:2016 | 04 | 2016 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $52,211 | $10,000 | Not Implemented |
NC0566 # 05 Y:2016 | 05 | 2016 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $107,179 | $300,000 | Not Implemented |
NC0566 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,988 | $100 | Implemented |
NC0566 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $788 | $200 | Implemented |
NC0566 # 08 Y:2016 | 08 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,802 | $12,000 | Not Implemented |
NC0566 # 09 Y:2016 | 09 | 2016 | REPAIR AND ELIMINATE STEAM LEAKS | $2,230 | $1,000 | Implemented |
NC0566 # 10 Y:2016 | 10 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,287 | $2,000 | Implemented |
NC0566 # 11 Y:2016 | 11 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $4,453 | $4,256 | Implemented |
NC0566 # 12 Y:2016 | 12 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,706 | $230 | Implemented |
NC0570 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,102 | $41,992 | Implemented |
NC0570 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $497 | $606 | Implemented |
NC0570 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $362 | $400 | Implemented |
NC0570 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,219 | $180 | Not Implemented |
NC0570 # 05 Y:2016 | 05 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $416 | $200 | Implemented |
NC0570 # 06 Y:2016 | 06 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $480 | $1,600 | Not Implemented |
NC0570 # 07 Y:2016 | 07 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $266 | $100 | Not Implemented |
NC0570 # 08 Y:2016 | 08 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $1,911 | $5,685 | Not Implemented |
NC0569 # 01 Y:2016 | 01 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $68,453 | $280,000 | Not Implemented |
NC0569 # 02 Y:2016 | 02 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,493 | $48,500 | Not Implemented |