Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
186
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0145 # 02 Y:1998 | 02 | 1998 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $33,755 | $125,000 | Not Implemented |
NC0145 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $434 | $25 | Not Implemented |
NC0145 # 04 Y:1998 | 04 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,308 | $200 | Not Implemented |
NC0145 # 05 Y:1998 | 05 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,875 | $100 | Implemented |
NC0145 # 06 Y:1998 | 06 | 1998 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,125 | $150 | Implemented |
NC0145 # 07 Y:1998 | 07 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $9,088 | $1,200 | Not Implemented |
NC0145 # 08 Y:1998 | 08 | 1998 | $111,500 | $405,000 | Not Implemented | |
NC0149 # 06 Y:1998 | 06 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,320 | $800 | Implemented |
NC0149 # 03 Y:1998 | 03 | 1998 | $6,400 | $1,000 | Implemented | |
NC0149 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,438 | $100 | Implemented |
NC0149 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $79,194 | $118,650 | Not Implemented |
NC0149 # 05 Y:1998 | 05 | 1998 | RECYCLE CLEANING SOLVENT AND REUSE | $1,472 | $100 | Implemented |
NC0149 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $938 | $200 | Implemented |
NC0150 # 01 Y:1998 | 01 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $920 | $400 | Not Implemented |
NC0150 # 02 Y:1998 | 02 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,383 | $819 | Not Implemented |
NC0150 # 03 Y:1998 | 03 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $729 | $1,532 | Not Implemented |
NC0150 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $244 | $800 | Implemented |
NC0150 # 06 Y:1998 | 06 | 1998 | USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS | $14,434 | $500 | Not Implemented |
NC0150 # 07 Y:1998 | 07 | 1998 | $45,216 | $16,000 | Not Implemented | |
NC0150 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,244 | $4,400 | Implemented |
NC0148 # 03 Y:1998 | 03 | 1998 | $7,677 | $10,000 | Implemented | |
NC0148 # 04 Y:1998 | 04 | 1998 | $63,429 | $80,000 | Implemented | |
NC0148 # 02 Y:1998 | 02 | 1998 | REDUCE FLUID FLOW RATES | $304 | $550 | Implemented |
NC0148 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,914 | $10,000 | Not Implemented |
NC0144 # 02 Y:1998 | 02 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,664 | $1,000 | Implemented |