Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,985
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0495 # 07 Y:2013 | 07 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,730 | $60,000 | Not Implemented |
NC0495 # 08 Y:2013 | 08 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $748 | $100 | Not Implemented |
NC0495 # 09 Y:2013 | 09 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $123 | $600 | Not Implemented |
NC0495 # 10 Y:2013 | 10 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,400 | $100 | Not Implemented |
NC0492 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $8,471 | $13,495 | Not Implemented |
NC0492 # 02 Y:2013 | 02 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,492 | $1,140 | Implemented |
NC0492 # 03 Y:2013 | 03 | 2013 | USE PHOTOCELL CONTROLS | $259 | $250 | Not Implemented |
NC0492 # 04 Y:2013 | 04 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,869 | $100 | Not Implemented |
NC0492 # 05 Y:2013 | 05 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $688 | $0 | Implemented |
NC0492 # 06 Y:2013 | 06 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $20,838 | $12,000 | Not Implemented |
NC0492 # 07 Y:2013 | 07 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $60 | $90 | Not Implemented |
NC0493 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,789 | $215,791 | Implemented |
NC0493 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,370 | $36,172 | Not Implemented |
NC0493 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $3,826 | $7,934 | Not Implemented |
NC0493 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,550 | $1,386 | Implemented |
NC0493 # 05 Y:2013 | 05 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,850 | $6,372 | Implemented |
NC0493 # 06 Y:2013 | 06 | 2013 | INSULATE BARE EQUIPMENT | $15,385 | $1,820 | Not Implemented |
NC0493 # 07 Y:2013 | 07 | 2013 | INSTALL / REPAIR INSULATION ON STEAM LINES | $853 | $1,447 | Not Implemented |
NC0493 # 08 Y:2013 | 08 | 2013 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,410 | $10,000 | Not Implemented |
NC0493 # 09 Y:2013 | 09 | 2013 | REDUCE EXCESSIVE BOILER BLOWDOWN | $430 | $0 | Implemented |
NC0493 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,165 | $100 | Implemented |
NC0493 # 11 Y:2013 | 11 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,410 | $15,000 | Not Implemented |
NC0493 # 12 Y:2013 | 12 | 2013 | TREAT AND REUSE RINSE WATERS | $28,586 | $90,000 | Not Implemented |
NC0493 # 13 Y:2013 | 13 | 2013 | CONDENSE OPERATION INTO ONE BUILDING | $21,473 | $10,000 | Implemented |
NC0491 # 01 Y:2013 | 01 | 2013 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $13,288 | $25,000 | Not Implemented |