Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

384

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0489 # 02 Y:2013 02 2013 USE PHOTOCELL CONTROLS $3,519 $1,000 Not Implemented
NC0489 # 03 Y:2013 03 2013 INSTALL OCCUPANCY SENSORS $1,103 $971 Not Implemented
NC0489 # 04 Y:2013 04 2013 RECOVER WASTE HEAT FROM EQUIPMENT $10,150 $1,500 Not Implemented
NC0489 # 05 Y:2013 05 2013 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $2,517 $50 Not Implemented
NC0489 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $808 $100 Implemented
NC0480 # 01 Y:2013 01 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $481 $1,490 Implemented
NC0480 # 02 Y:2013 02 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,008 $4,271 Implemented
NC0480 # 03 Y:2013 03 2013 INSTALL OCCUPANCY SENSORS $297 $264 Implemented
NC0480 # 04 Y:2013 04 2013 USE PHOTOCELL CONTROLS $1,282 $1,250 Implemented
NC0480 # 05 Y:2013 05 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,460 $100 Implemented
NC0480 # 06 Y:2013 06 2013 DEVELOP A REPAIR/REPLACE POLICY $6,224 $13,210 Implemented
NC0480 # 07 Y:2013 07 2013 USE PHOTOCELL CONTROLS $4,207 $15,472 Not Implemented
NC0447 # 01 Y:2012 01 2012 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $2,468 $500 Implemented
NC0447 # 02 Y:2012 02 2012 INSULATE BARE EQUIPMENT $17,983 $2,000 Not Implemented
NC0447 # 03 Y:2012 03 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,895 $400 Implemented
NC0447 # 04 Y:2012 04 2012 INSULATE FEEDWATER TANK $339 $1,133 Not Implemented
NC0447 # 05 Y:2012 05 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,779 $84,121 Not Implemented
NC0447 # 06 Y:2012 06 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,190 $399 Not Implemented
NC0435 # 01 Y:2011 01 2011 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $23,638 $0 Not Implemented
NC0435 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $44,479 $72,211 Implemented
NC0435 # 03 Y:2011 03 2011 INSTALL SPECTRAL REFLECTORS / DELAMP $1,887 $7,760 Implemented
NC0435 # 04 Y:2011 04 2011 INSTALL OCCUPANCY SENSORS $661 $1,911 Implemented
NC0435 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $124 $31 Not Implemented
NC0435 # 06 Y:2011 06 2011 INSTALL TIMERS AND/OR THERMOSTATS $295 $1,500 Implemented
NC0417 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $101,691 $362,675 Not Implemented