Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
33
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0128 # 04 Y:1997 | 04 | 1997 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $28,209 | $17,238 | Not Implemented |
NC0128 # 08 Y:1997 | 08 | 1997 | OPERATE BOILERS ON HIGH FIRE SETTING | $19,152 | $2,000 | Implemented |
NC0128 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $92 | $140 | Not Implemented |
NC0128 # 05 Y:1997 | 05 | 1997 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $18,878 | $49,000 | Not Implemented |
NC0128 # 06 Y:1997 | 06 | 1997 | INSULATE BARE EQUIPMENT | $1,956 | $3,655 | Implemented |
NC0128 # 10 Y:1997 | 10 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $96 | $4,200 | Implemented |
NC0128 # 07 Y:1997 | 07 | 1997 | AIR CONDITION ONLY SPACE NECESSARY | $3,389 | $7,155 | Not Implemented |
NC0128 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $445 | $1,260 | Not Implemented |
NC0128 # 03 Y:1997 | 03 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $799 | $700 | Not Implemented |
NC0128 # 09 Y:1997 | 09 | 1997 | REDUCE SCRAP PRODUCTION | $1,288 | $250 | Not Implemented |
NC0128 # 11 Y:1997 | 11 | 1997 | $140,000 | $300,000 | Implemented | |
NC0123 # 12 Y:1997 | 12 | 1997 | $115,000 | $200,000 | Implemented | |
NC0123 # 11 Y:1997 | 11 | 1997 | $10,775 | $0 | Implemented | |
NC0123 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $126 | $25 | Not Implemented |
NC0123 # 10 Y:1997 | 10 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $375 | $200 | Implemented |
NC0123 # 09 Y:1997 | 09 | 1997 | REDUCE SCRAP PRODUCTION | $3,429 | $15,000 | Not Implemented |
NC0123 # 08 Y:1997 | 08 | 1997 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $14,528 | $12,000 | Not Implemented |
NC0123 # 07 Y:1997 | 07 | 1997 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $926 | $200 | Not Implemented |
NC0123 # 06 Y:1997 | 06 | 1997 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,282 | $14,319 | Not Implemented |
NC0123 # 05 Y:1997 | 05 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $376 | $400 | Not Implemented |
NC0123 # 03 Y:1997 | 03 | 1997 | ADD AREA LIGHTING SWITCHES | $1,475 | $2,000 | Not Implemented |
NC0123 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $953 | $450 | Not Implemented |
NC0123 # 01 Y:1997 | 01 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,987 | $0 | Implemented |
NC0118 # 06 Y:1997 | 06 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,960 | $606 | Not Implemented |
NC0118 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $27,676 | $0 | Implemented |