Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,124
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NV0053 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,194 | $300 | Implemented |
NV0053 # 04 Y:1996 | 04 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $857 | $1,625 | Not Implemented |
NV0053 # 05 Y:1996 | 05 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $706 | $25 | Not Implemented |
NV0053 # 06 Y:1996 | 06 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,604 | $9,740 | Not Implemented |
NV0053 # 07 Y:1996 | 07 | 1996 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $598 | $1,400 | Not Implemented |
NV0053 # 08 Y:1996 | 08 | 1996 | INSULATE BARE EQUIPMENT | $3,287 | $878 | Implemented |
NV0053 # 09 Y:1996 | 09 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $3,417 | $1,504 | Implemented |
NV0053 # 10 Y:1996 | 10 | 1996 | RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS | $205 | $340 | Not Implemented |
NV0053 # 11 Y:1996 | 11 | 1996 | HEAT WATER WITH EXHAUST HEAT | $9,600 | $1,000 | Not Implemented |
NV0052 # 01 Y:1996 | 01 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $1,741 | $100 | Not Implemented |
NV0052 # 02 Y:1996 | 02 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,689 | $3,250 | Not Implemented |
NV0052 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $121 | $100 | Implemented |
NV0052 # 04 Y:1996 | 04 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $4,914 | $0 | Implemented |
NV0051 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $469 | $81 | Implemented |
NV0051 # 02 Y:1996 | 02 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $727 | $1,625 | Not Implemented |
NV0051 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $930 | $300 | Implemented |
NV0051 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $820 | $0 | Not Implemented |
NV0051 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $185 | $0 | Implemented |
NV0051 # 06 Y:1996 | 06 | 1996 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $18,575 | $17,350 | Implemented |
NV0050 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $57,460 | $140,000 | Implemented |
NV0050 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,043 | $300 | Implemented |
NV0050 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,040 | $2,200 | Implemented |
NV0050 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $842 | $521 | Implemented |
NV0050 # 05 Y:1996 | 05 | 1996 | SELL COMBUSTIBLE WASTE | $2,500 | $520 | Implemented |
NV0049 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,748 | $993 | Not Implemented |