Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
151
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0648 # 10 Y:2002 | 10 | 2002 | COVER OPEN TANKS | $1,983 | $752 | Not Implemented |
OK0648 # 01 Y:2002 | 01 | 2002 | USE OPTIMUM THICKNESS INSULATION | $12,108 | $2,317 | Implemented |
OK0646 # 05 Y:2002 | 05 | 2002 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $113 | $60 | Not Implemented |
OK0646 # 04 Y:2002 | 04 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $13,960 | $0 | Implemented |
OK0646 # 03 Y:2002 | 03 | 2002 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $659 | $0 | Implemented |
OK0646 # 02 Y:2002 | 02 | 2002 | INSTALL SET-BACK TIMERS | $469 | $93 | Implemented |
OK0646 # 01 Y:2002 | 01 | 2002 | OPTIMIZE PLANT POWER FACTOR | $1,976 | $3,150 | Not Implemented |
OK0646 # 08 Y:2002 | 08 | 2002 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $8,334 | $9,000 | Not Implemented |
OK0646 # 06 Y:2002 | 06 | 2002 | UPGRADE CONTROLS ON COMPRESSORS | $1,858 | $150 | Not Implemented |
OK0646 # 07 Y:2002 | 07 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,545 | $5,270 | Implemented |
OK0652 # 01 Y:2002 | 01 | 2002 | INSTALL SET-BACK TIMERS | $2,551 | $20 | Implemented |
OK0652 # 09 Y:2002 | 09 | 2002 | $23,400 | $15,000 | Not Implemented | |
OK0652 # 02 Y:2002 | 02 | 2002 | INSTALL OCCUPANCY SENSORS | $482 | $441 | Not Implemented |
OK0652 # 06 Y:2002 | 06 | 2002 | INSTALL SKYLIGHTS | $3,503 | $22,350 | Not Implemented |
OK0652 # 03 Y:2002 | 03 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,884 | $26,000 | Not Implemented |
OK0652 # 04 Y:2002 | 04 | 2002 | $37,928 | $6,058 | Not Implemented | |
OK0652 # 08 Y:2002 | 08 | 2002 | $33,280 | $4,000 | Not Implemented | |
OK0652 # 05 Y:2002 | 05 | 2002 | $2,600 | $515 | Not Implemented | |
OK0652 # 07 Y:2002 | 07 | 2002 | $16,640 | $25,000 | Not Implemented | |
OK0647 # 08 Y:2002 | 08 | 2002 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $87,000 | $5,400 | Not Implemented |
OK0647 # 01 Y:2002 | 01 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $42,712 | $2,250 | Implemented |
OK0647 # 02 Y:2002 | 02 | 2002 | INSULATE BARE EQUIPMENT | $29,330 | $9,344 | Implemented |
OK0647 # 09 Y:2002 | 09 | 2002 | INSTALL SET-BACK TIMERS | $1,446 | $372 | Implemented |
OK0647 # 07 Y:2002 | 07 | 2002 | $166,400 | $208,754 | Implemented | |
OK0647 # 03 Y:2002 | 03 | 2002 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $21,369 | $15,150 | Not Implemented |