Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
144
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0075 # 06 Y:1989 | 06 | 1989 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $833 | $1,175 | Implemented |
OR0074 # 03 Y:1989 | 03 | 1989 | OPTIMIZE PLANT POWER FACTOR | $498 | $1,125 | Implemented |
OR0075 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $228 | $213 | Implemented |
OR0075 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $78 | $94 | Implemented |
OR0075 # 01 Y:1989 | 01 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $794 | $500 | Implemented |
OR0074 # 04 Y:1989 | 04 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $200 | $250 | Implemented |
OR0074 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $171 | $223 | Implemented |
OR0075 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $131 | $244 | Implemented |
OR0070 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,697 | $2,400 | Implemented |
OR0073 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $872 | $883 | Implemented |
OR0071 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $106 | $181 | Implemented |
OR0070 # 03 Y:1989 | 03 | 1989 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $3,909 | $1,090 | Implemented |
OR0072 # 01 Y:1989 | 01 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $134 | $200 | Implemented |
OR0073 # 01 Y:1989 | 01 | 1989 | RECOVER AND REUSE COOLING WATER | $2,582 | $434 | Implemented |
OR0070 # 08 Y:1989 | 08 | 1989 | OPTIMIZE PLANT POWER FACTOR | $1,625 | $3,450 | Implemented |
OR0070 # 05 Y:1989 | 05 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,113 | $1,204 | Implemented |
OR0073 # 06 Y:1989 | 06 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $770 | $1,000 | Implemented |
OR0070 # 06 Y:1989 | 06 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $232 | $250 | Implemented |
OR0071 # 05 Y:1989 | 05 | 1989 | REDUCE FLUID FLOW RATES | $4,615 | $12,560 | Implemented |
OR0070 # 04 Y:1989 | 04 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $8,766 | $0 | Implemented |
OR0073 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,024 | $2,931 | Implemented |
OR0070 # 07 Y:1989 | 07 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,260 | $2,000 | Implemented |
OR0070 # 01 Y:1989 | 01 | 1989 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $13,228 | $2,500 | Implemented |
OR0073 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,597 | $0 | Implemented |
OR0071 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,682 | $5,000 | Implemented |