Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,948
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0052 # 08 Y:1989 | 08 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $259 | $395 | Implemented |
OR0049 # 01 Y:1989 | 01 | 1989 | INSTALL SET-BACK TIMERS | $25,856 | $0 | Implemented |
OR0049 # 02 Y:1989 | 02 | 1989 | OPTIMIZE PLANT POWER FACTOR | $12,480 | $10,000 | Implemented |
OR0049 # 03 Y:1989 | 03 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $607 | $500 | Implemented |
OR0049 # 04 Y:1989 | 04 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $2,770 | $3,720 | Not Implemented |
OR0049 # 05 Y:1989 | 05 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $132 | $206 | Implemented |
OR0049 # 06 Y:1989 | 06 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $996 | $2,000 | Implemented |
OR0047 # 01 Y:1989 | 01 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $8,348 | $0 | Implemented |
OR0047 # 02 Y:1989 | 02 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $5,777 | $0 | Implemented |
OR0047 # 03 Y:1989 | 03 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,193 | $0 | Implemented |
OR0047 # 04 Y:1989 | 04 | 1989 | INSTALL SET-BACK TIMERS | $3,718 | $0 | Implemented |
OR0047 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,679 | $500 | Implemented |
OR0047 # 06 Y:1989 | 06 | 1989 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $544 | $650 | Not Implemented |
OR0047 # 07 Y:1989 | 07 | 1989 | INSULATE FEEDWATER TANK | $435 | $658 | Implemented |
OR0047 # 08 Y:1989 | 08 | 1989 | OPTIMIZE PLANT POWER FACTOR | $3,159 | $6,810 | Implemented |
OR0048 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $519 | $500 | Not Implemented |
OR0048 # 02 Y:1989 | 02 | 1989 | RECOVER AND REUSE COOLING WATER | $622 | $316 | Implemented |
OR0048 # 03 Y:1989 | 03 | 1989 | RECOVER AND REUSE COOLING WATER | $473 | $402 | Implemented |
OR0048 # 04 Y:1989 | 04 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $135 | $138 | Not Implemented |
OR0048 # 05 Y:1989 | 05 | 1989 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,545 | $7,500 | Implemented |
OR0048 # 06 Y:1989 | 06 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,327 | $13,600 | Not Implemented |
OR0048 # 07 Y:1989 | 07 | 1989 | OPTIMIZE PLANT POWER FACTOR | $592 | $1,500 | Implemented |
OR0042 # 05 Y:1988 | 05 | 1988 | OPTIMIZE PLANT POWER FACTOR | $2,293 | $4,800 | Implemented |
OR0042 # 06 Y:1988 | 06 | 1988 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $36,759 | $0 | Not Implemented |
OR0043 # 01 Y:1988 | 01 | 1988 | USE MINIMUM STEAM OPERATING PRESSURE | $506 | $0 | Implemented |