Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
214
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0131 # 08 Y:1991 | 08 | 1991 | REDUCE FLUID FLOW RATES | $4,213 | $7,624 | Implemented |
OR0131 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $9,083 | $0 | Implemented |
OR0131 # 06 Y:1991 | 06 | 1991 | INSULATE BARE EQUIPMENT | $2,749 | $4,500 | Implemented |
OR0131 # 09 Y:1991 | 09 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,150 | $7,200 | Implemented |
OR0131 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $922 | $1,763 | Implemented |
OR0131 # 02 Y:1991 | 02 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,408 | $500 | Implemented |
OR0131 # 05 Y:1991 | 05 | 1991 | INSULATE BARE EQUIPMENT | $1,320 | $1,914 | Implemented |
OR0131 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,465 | $0 | Implemented |
OR0131 # 03 Y:1991 | 03 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,517 | $1,000 | Implemented |
OR0125 # 03 Y:1991 | 03 | 1991 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,391 | $35,042 | Implemented |
OR0132 # 08 Y:1991 | 08 | 1991 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,040 | $1,200 | Implemented |
OR0133 # 01 Y:1991 | 01 | 1991 | INSTALL SET-BACK TIMERS | $1,035 | $0 | Implemented |
OR0125 # 02 Y:1991 | 02 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,392 | $6,072 | Implemented |
OR0132 # 06 Y:1991 | 06 | 1991 | HEAT WATER WITH EXHAUST HEAT | $6,513 | $5,744 | Implemented |
OR0132 # 03 Y:1991 | 03 | 1991 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,074 | $500 | Implemented |
OR0125 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,743 | $0 | Implemented |
OR0135 # 06 Y:1991 | 06 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $124 | $0 | Implemented |
OR0132 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $878 | $5,922 | Implemented |
OR0132 # 01 Y:1991 | 01 | 1991 | INSTALL SET-BACK TIMERS | $736 | $0 | Implemented |
OR0132 # 05 Y:1991 | 05 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,538 | $1,000 | Implemented |
OR0132 # 10 Y:1991 | 10 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,450 | $10,200 | Implemented |
OR0132 # 09 Y:1991 | 09 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $632 | $898 | Implemented |
OR0132 # 04 Y:1991 | 04 | 1991 | RECOVER AND REUSE COOLING WATER | $2,804 | $1,727 | Implemented |
OR0125 # 05 Y:1991 | 05 | 1991 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,934 | $83,040 | Implemented |
OR0132 # 02 Y:1991 | 02 | 1991 | TURN OFF EQUIPMENT WHEN NOT IN USE | $317 | $0 | Not Implemented |