Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
169
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0255 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,209 | $3,511 | Implemented |
OR0255 # 06 Y:1995 | 06 | 1995 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $104,000 | $250,000 | Not Implemented |
OR0255 # 07 Y:1995 | 07 | 1995 | MINIMIZE WATER USAGE | $5,927 | $1,153 | Implemented |
OR0255 # 09 Y:1995 | 09 | 1995 | MINIMIZE WATER USAGE | $3,344 | $600 | Not Implemented |
OR0255 # 11 Y:1995 | 11 | 1995 | MINIMIZE WATER USAGE | $1,279 | $434 | Not Implemented |
OR0255 # 10 Y:1995 | 10 | 1995 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $1,952 | $489 | Not Implemented |
OR0255 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $1,080 | $3,600 | Not Implemented |
OR0255 # 08 Y:1995 | 08 | 1995 | MINIMIZE WATER USAGE | $3,418 | $148 | Implemented |
OR0255 # 01 Y:1995 | 01 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,563 | $0 | Implemented |
OR0255 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,071 | $0 | Implemented |
OR0255 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,688 | $4,179 | Not Implemented |
OR0254 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,069 | $2,353 | Implemented |
OR0254 # 07 Y:1995 | 07 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,299 | $0 | Implemented |
OR0254 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,247 | $0 | Not Implemented |
OR0254 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $2,665 | $2,500 | Not Implemented |
OR0254 # 06 Y:1995 | 06 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $1,648 | $200 | Not Implemented |
OR0254 # 04 Y:1995 | 04 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,477 | $0 | Not Implemented |
OR0254 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $525 | $425 | Implemented |
OR0252 # 04 Y:1995 | 04 | 1995 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $14,230 | $0 | Implemented |
OR0252 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,876 | $8,563 | Implemented |
OR0252 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $895 | $1,734 | Implemented |
OR0252 # 03 Y:1995 | 03 | 1995 | REDUCE SCRAP PRODUCTION | $12,740 | $0 | Not Implemented |
OR0253 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $29,097 | $26,200 | Not Implemented |
OR0253 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,790 | $5,000 | Not Implemented |
OR0253 # 03 Y:1995 | 03 | 1995 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $11,142 | $0 | Not Implemented |