IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,027

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0006 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $3,147 $648 Not Implemented
RU0006 # 03 Y:1987 03 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,672 $0 Implemented
RU0006 # 04 Y:1987 04 1987 IMPROVE LUBRICATION PRACTICES $832 $0 Not Implemented
RU0006 # 05 Y:1987 05 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,154 $5,600 Not Implemented
RU0006 # 06 Y:1987 06 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,856 $9,500 Not Implemented
RU0006 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $718 $1,204 Implemented
RU0003 # 01 Y:1987 01 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,895 $7,500 Implemented
RU0003 # 02 Y:1987 02 1987 REPAIR OR REPLACE STEAM TRAPS $88,019 $30,000 Implemented
RU0003 # 03 Y:1987 03 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $756 $72 Not Implemented
RU0003 # 04 Y:1987 04 1987 IMPROVE LUBRICATION PRACTICES $1,154 $0 Not Implemented
RU0003 # 05 Y:1987 05 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $48,442 $750 Implemented
RU0005 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,958 $184 Implemented
RU0005 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $791 $84 Implemented
RU0005 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $6,186 $292 Implemented
RU0005 # 04 Y:1987 04 1987 UPGRADE OBSOLETE EQUIPMENT $1,486 $0 Not Implemented
RU0005 # 05 Y:1987 05 1987 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,688 $0 Implemented
RU0001 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,628 $376 Implemented
RU0001 # 02 Y:1987 02 1987 COVER OPEN TANKS $3,290 $200 Not Implemented
RU0001 # 03 Y:1987 03 1987 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $822 $31 Implemented
RU0001 # 04 Y:1987 04 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,104 $0 Implemented
RU0001 # 05 Y:1987 05 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,551 $0 Implemented
RU0002 # 01 Y:1987 01 1987 IMPROVE LUBRICATION PRACTICES $22,514 $0 Implemented
RU0002 # 02 Y:1987 02 1987 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $30,280 $32,000 Implemented
RU0002 # 03 Y:1987 03 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,433 $5,670 Implemented
RU0002 # 04 Y:1987 04 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,800 $178 Implemented