Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
224
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0121 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $656 | $702 | Implemented |
SD0121 # 02 Y:1995 | 02 | 1995 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $3,648 | $977 | Implemented |
SD0121 # 01 Y:1995 | 01 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,420 | $7,500 | Implemented |
SD0119 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,196 | $8,381 | Implemented |
SD0119 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,107 | $4,150 | Implemented |
SD0119 # 02 Y:1995 | 02 | 1995 | INSULATE BARE EQUIPMENT | $4,410 | $4,925 | Not Implemented |
SD0119 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,610 | $493 | Implemented |
SD0119 # 04 Y:1995 | 04 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,483 | $2,500 | Implemented |
SD0119 # 07 Y:1995 | 07 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,758 | $6,675 | Implemented |
SD0120 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $1,161 | $880 | Not Implemented |
SD0120 # 06 Y:1995 | 06 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,836 | $3,940 | Implemented |
SD0120 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,430 | $5,990 | Implemented |
SD0120 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $809 | $1,970 | Implemented |
SD0120 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,871 | $2,761 | Implemented |
SD0120 # 02 Y:1995 | 02 | 1995 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $77,121 | $121,250 | Implemented |
SD0120 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,166 | $1,030 | Implemented |
SD0119 # 12 Y:1995 | 12 | 1995 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $600 | $0 | Implemented |
SD0119 # 11 Y:1995 | 11 | 1995 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $936 | $0 | Implemented |
SD0119 # 05 Y:1995 | 05 | 1995 | COVER OPEN TANKS | $593 | $227 | Implemented |
SD0119 # 08 Y:1995 | 08 | 1995 | INSTALL OCCUPANCY SENSORS | $995 | $648 | Not Implemented |
SD0119 # 09 Y:1995 | 09 | 1995 | USE PHOTOCELL CONTROLS | $526 | $300 | Not Implemented |
SD0119 # 10 Y:1995 | 10 | 1995 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $17,352 | $7,000 | Not Implemented |
SD0118 # 02 Y:1995 | 02 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,560 | $20 | Implemented |
SD0118 # 08 Y:1995 | 08 | 1995 | IMPROVE CLEANING EFFICIENCY BY MAINTAINING CLEANING SYSTEM | $3,902 | $500 | Implemented |
SD0118 # 03 Y:1995 | 03 | 1995 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $202 | $300 | Implemented |