Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

214

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0301 # 01 Y:2002 01 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $30,135 $58,000 Not Implemented
SD0301 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,968 $320 Not Implemented
SD0301 # 03 Y:2002 03 2002 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $3,733 $1,000 Not Implemented
SD0301 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $2,775 $6,000 Not Implemented
SD0301 # 06 Y:2002 06 2002 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $1,586 $1,000 Not Implemented
SD0301 # 07 Y:2002 07 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $1,584 $2,000 Not Implemented
SD0301 # 08 Y:2002 08 2002 INCREASE USE OF AUTOMATION $51,000 $50,000 Not Implemented
SD0300 # 04 Y:2002 04 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,056 $14,800 Not Implemented
SD0300 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,870 $520 Implemented
SD0300 # 02 Y:2002 02 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,208 $20,000 Not Implemented
SD0300 # 03 Y:2002 03 2002 USE PHOTOCELL CONTROLS $8,501 $9,000 Not Implemented
SD0300 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,105 $0 Not Implemented
SD0300 # 07 Y:2002 07 2002 UTILIZE A LESS EXPENSIVE COOLING METHOD $11,000 $0 Not Implemented
SD0300 # 06 Y:2002 06 2002 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $5,500 $10,000 Implemented
SD0300 # 08 Y:2002 08 2002 INCREASE USE OF AUTOMATION $42,640 $20,000 Not Implemented
SD0300 # 09 Y:2002 09 2002 INCREASE USE OF AUTOMATION $2,296 $3,500 Not Implemented
SD0300 # 10 Y:2002 10 2002 PAY UTILITY BILLS ON TIME $426 $0 Not Implemented
SD0299 # 08 Y:2002 08 2002 WASH AND REUSE RAGS ON-SITE $3,040 $5,000 Not Implemented
SD0299 # 07 Y:2002 07 2002 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $4,300 $3,000 Implemented
SD0299 # 06 Y:2002 06 2002 INSTALL OCCUPANCY SENSORS $376 $250 Not Implemented
SD0299 # 05 Y:2002 05 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $752 $0 Not Implemented
SD0299 # 01 Y:2002 01 2002 INSTALL SKYLIGHTS $3,373 $5,200 Not Implemented
SD0299 # 04 Y:2002 04 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $2,238 $400 Not Implemented
SD0299 # 03 Y:2002 03 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $2,389 $0 Not Implemented
SD0299 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,114 $4,526 Not Implemented