Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
236
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0210 # 03 Y:1998 | 03 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $8,860 | $3,100 | Not Implemented |
SD0210 # 02 Y:1998 | 02 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,500 | $36,250 | Not Implemented |
SD0210 # 01 Y:1998 | 01 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $901 | $0 | Not Implemented |
SD0209 # 10 Y:1998 | 10 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $10,300 | $8,000 | Not Implemented |
SD0209 # 07 Y:1998 | 07 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $108,568 | $13,000 | Not Implemented |
SD0209 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,718 | $2,500 | Not Implemented |
SD0209 # 08 Y:1998 | 08 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $22,000 | $0 | Not Implemented |
SD0209 # 05 Y:1998 | 05 | 1998 | USE A RAG RECYCLE SERVICE | $10,318 | $1,200 | Implemented |
SD0209 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $177,242 | $44,000 | Not Implemented |
SD0209 # 03 Y:1998 | 03 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,717 | $1,000 | Not Implemented |
SD0209 # 04 Y:1998 | 04 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,228 | $0 | Implemented |
SD0209 # 09 Y:1998 | 09 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $89,794 | $81,000 | Not Implemented |
SD0209 # 06 Y:1998 | 06 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $331,304 | $21,000 | Not Implemented |
SD0208 # 03 Y:1998 | 03 | 1998 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $10,888 | $2,500 | Not Implemented |
SD0208 # 06 Y:1998 | 06 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $353,400 | $310,000 | Not Implemented |
SD0208 # 02 Y:1998 | 02 | 1998 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $36,215 | $3,000 | Not Implemented |
SD0208 # 01 Y:1998 | 01 | 1998 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $78,408 | $16,000 | Not Implemented |
SD0208 # 05 Y:1998 | 05 | 1998 | RECYCLE WHITE WATER | $12,375 | $5,000 | Implemented |
SD0208 # 04 Y:1998 | 04 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,843 | $2,700 | Implemented |
SD0207 # 08 Y:1998 | 08 | 1998 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $1,164 | $0 | Not Implemented |
SD0207 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $36,824 | $4,285 | Not Implemented |
SD0207 # 07 Y:1998 | 07 | 1998 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $12,929 | $8,000 | Not Implemented |
SD0207 # 06 Y:1998 | 06 | 1998 | TREAT AND REUSE RINSE WATERS | $2,126 | $300 | Not Implemented |
SD0207 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $254 | $0 | Not Implemented |
SD0207 # 02 Y:1998 | 02 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,302 | $0 | Not Implemented |