Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0229 # 08 Y:1999 | 08 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $76,320 | $30,000 | Not Implemented |
SD0229 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,875 | $2,988 | Implemented |
SD0229 # 07 Y:1999 | 07 | 1999 | INSTALL BACK-UP EQUIPMENT | $23,040 | $15,000 | Not Implemented |
SD0229 # 02 Y:1999 | 02 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,528 | $10,000 | Not Implemented |
SD0229 # 05 Y:1999 | 05 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,502 | $11,000 | Not Implemented |
SD0229 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,665 | $500 | Implemented |
SD0229 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,377 | $120 | Implemented |
SD0229 # 06 Y:1999 | 06 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,372 | $540 | Not Implemented |
SD0230 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $39,860 | $16,000 | Not Implemented |
SD0230 # 07 Y:1999 | 07 | 1999 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $27,200 | $0 | Implemented |
SD0230 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,483 | $6,030 | Not Implemented |
SD0230 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,090 | $4,048 | Implemented |
SD0230 # 08 Y:1999 | 08 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $0 | $2,410 | Implemented |
SD0230 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $83,680 | $0 | Implemented |
SD0230 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,099,432 | $1,975,633 | Not Implemented |
SD0230 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $257,414 | $480,000 | Not Implemented |
SD0235 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,218 | $23,830 | Implemented |
SD0235 # 03 Y:1999 | 03 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,356 | $0 | Not Implemented |
SD0235 # 05 Y:1999 | 05 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,852 | $0 | Not Implemented |
SD0235 # 07 Y:1999 | 07 | 1999 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $7,690 | $0 | Not Implemented |
SD0235 # 14 Y:1999 | 14 | 1999 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,362 | $1,078 | Implemented |
SD0235 # 09 Y:1999 | 09 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $34,580 | $20,000 | Not Implemented |
SD0235 # 06 Y:1999 | 06 | 1999 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,794 | $14,000 | Not Implemented |
SD0235 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,382 | $7,776 | Not Implemented |
SD0235 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,361 | $1,782 | Not Implemented |