Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
87
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0227 # 07 Y:2001 | 07 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $24,960 | $30,230 | Implemented |
SF0227 # 06 Y:2001 | 06 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $807,300 | $190,000 | Implemented |
SF0227 # 05 Y:2001 | 05 | 2001 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,077 | $52 | Implemented |
SF0227 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $580 | $4,298 | Implemented |
SF0227 # 02 Y:2001 | 02 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,747 | $1,200 | Implemented |
SF0227 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,362 | $0 | Implemented |
SF0226 # 05 Y:2001 | 05 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $35,839 | $11,800 | Implemented |
SF0226 # 06 Y:2001 | 06 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $844 | $535 | Implemented |
SF0226 # 07 Y:2001 | 07 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,016 | $3,275 | Implemented |
SF0226 # 08 Y:2001 | 08 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $3,717 | $2,500 | Implemented |
SF0226 # 10 Y:2001 | 10 | 2001 | INSTALL OCCUPANCY SENSORS | $1,758 | $2,040 | Implemented |
SF0226 # 11 Y:2001 | 11 | 2001 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $863 | $1,126 | Implemented |
SF0225 # 02 Y:2001 | 02 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,216 | $112 | Implemented |
SF0225 # 01 Y:2001 | 01 | 2001 | APPLY A PROTECTIVE COATING TO RACKS AND TANKS | $2,925 | $0 | Implemented |
SF0225 # 03 Y:2001 | 03 | 2001 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,948 | $2,195 | Implemented |
SF0223 # 01 Y:2001 | 01 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,905 | $0 | Implemented |
SF0223 # 04 Y:2001 | 04 | 2001 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,914 | $2,160 | Implemented |
SF0223 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $1,304 | $1,080 | Implemented |
SF0223 # 07 Y:2001 | 07 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,122 | $3,134 | Implemented |
SF0223 # 12 Y:2001 | 12 | 2001 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $450,000 | $50,000 | Implemented |
SF0223 # 06 Y:2001 | 06 | 2001 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $885 | $900 | Implemented |
SF0222 # 04 Y:2001 | 04 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,187 | $2,939 | Implemented |
SF0222 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,760 | $0 | Implemented |
SF0222 # 03 Y:2001 | 03 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,737 | $3,150 | Implemented |
SF0222 # 05 Y:2001 | 05 | 2001 | INSTALL OCCUPANCY SENSORS | $1,150 | $2,400 | Implemented |