Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0495 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $2,590 | $6,532 | Implemented |
SF0495 # 03 Y:2016 | 03 | 2016 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,562 | $3,136 | Not Implemented |
SF0495 # 06 Y:2016 | 06 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,109 | $0 | Not Implemented |
SF0495 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,370 | $6,127 | Implemented |
SF0495 # 01 Y:2016 | 01 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,207 | $661 | Implemented |
SF0495 # 04 Y:2016 | 04 | 2016 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $3,447 | $8,329 | Implemented |
SF0494 # 07 Y:2016 | 07 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $50,748 | $406,834 | Implemented |
SF0494 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $270 | $0 | Implemented |
SF0494 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,469 | $4,948 | Implemented |
SF0494 # 05 Y:2016 | 05 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,493 | $5,050 | Not Implemented |
SF0494 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $567 | $2,381 | Implemented |
SF0494 # 01 Y:2016 | 01 | 2016 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,238 | $0 | Implemented |
SF0494 # 03 Y:2016 | 03 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,772 | $2,510 | Implemented |
SF0493 # 05 Y:2016 | 05 | 2016 | USE SOLAR HEAT TO MAKE ELECTRICTY | $65,494 | $424,736 | Not Implemented |
SF0493 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,058 | $8,198 | Not Implemented |
SF0493 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $1,216 | $1,134 | Not Implemented |
SF0493 # 02 Y:2016 | 02 | 2016 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,064 | $1,350 | Implemented |
SF0493 # 01 Y:2016 | 01 | 2016 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $81,971 | $0 | Implemented |
SF0492 # 09 Y:2016 | 09 | 2016 | INSULATE BARE EQUIPMENT | $165 | $292 | Implemented |
SF0492 # 02 Y:2016 | 02 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $218 | $33 | Implemented |
SF0492 # 06 Y:2016 | 06 | 2016 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $8,794 | $15,281 | Implemented |
SF0492 # 12 Y:2016 | 12 | 2016 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,145 | $45,338 | Not Implemented |
SF0492 # 11 Y:2016 | 11 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $12,365 | $30,659 | Implemented |
SF0492 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,076 | $5,200 | Implemented |
SF0492 # 01 Y:2016 | 01 | 2016 | INCREASE AMOUNT OF CONDENSATE RETURNED | $13,265 | $280 | Implemented |