Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
85
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0252 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $6,105 | $8,772 | Implemented |
TN0252 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,557 | $180 | Implemented |
TN0252 # 04 Y:1985 | 04 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $732 | $3,720 | Implemented |
TN0263 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,113 | $11,950 | Implemented |
TN0263 # 03 Y:1985 | 03 | 1985 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,318 | $0 | Implemented |
TN0244 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,989 | $0 | Implemented |
TN0244 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $396 | $45 | Implemented |
TN0265 # 03 Y:1985 | 03 | 1985 | USE MINIMUM STEAM OPERATING PRESSURE | $3,947 | $0 | Implemented |
TN0265 # 04 Y:1985 | 04 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,386 | $75 | Implemented |
TN0265 # 05 Y:1985 | 05 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,474 | $7,430 | Implemented |
TN0265 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $896 | $115 | Implemented |
TN0265 # 07 Y:1985 | 07 | 1985 | INSTALL SET-BACK TIMERS | $498 | $0 | Implemented |
TN0266 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,445 | $600 | Implemented |
TN0266 # 04 Y:1985 | 04 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,054 | $0 | Implemented |
TN0266 # 08 Y:1985 | 08 | 1985 | INSTALL SET-BACK TIMERS | $618 | $0 | Implemented |
TN0261 # 07 Y:1985 | 07 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $92 | $0 | Implemented |
TN0261 # 06 Y:1985 | 06 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $111 | $35 | Implemented |
TN0261 # 05 Y:1985 | 05 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $129 | $100 | Implemented |
TN0261 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $554 | $300 | Implemented |
TN0261 # 03 Y:1985 | 03 | 1985 | INSTALL SET-BACK TIMERS | $628 | $0 | Implemented |
TN0261 # 02 Y:1985 | 02 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $1,200 | $75 | Implemented |
TN0267 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,967 | $0 | Implemented |
TN0267 # 02 Y:1985 | 02 | 1985 | INSULATE BARE EQUIPMENT | $5,424 | $2,400 | Implemented |
TN0267 # 03 Y:1985 | 03 | 1985 | REPAIR AND ELIMINATE STEAM LEAKS | $4,358 | $87 | Implemented |
TN0266 # 06 Y:1985 | 06 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $948 | $2,300 | Implemented |