Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,950
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0671 # 01 Y:1999 | 01 | 1999 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $250,000 | $2,030 | Not Implemented |
TN0671 # 02 Y:1999 | 02 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $108,400 | $34,670 | Not Implemented |
TN0671 # 03 Y:1999 | 03 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $45,000 | $16,375 | Not Implemented |
TN0671 # 04 Y:1999 | 04 | 1999 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $28,195 | $1,075 | Not Implemented |
TN0671 # 05 Y:1999 | 05 | 1999 | SELL / OFFER BY-PRODUCT AS ANIMAL FEED | $21,560 | $0 | Not Implemented |
TN0671 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $4,000 | $13,000 | Not Implemented |
TN0671 # 07 Y:1999 | 07 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,680 | $11,780 | Not Implemented |
TN0671 # 08 Y:1999 | 08 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $360 | $305 | Not Implemented |
TN0670 # 01 Y:1999 | 01 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $30,906 | $3,200 | Implemented |
TN0670 # 02 Y:1999 | 02 | 1999 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $20,663 | $16,000 | Not Implemented |
TN0670 # 03 Y:1999 | 03 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $6,283 | $3,000 | Implemented |
TN0670 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $640 | $1,250 | Implemented |
TN0670 # 05 Y:1999 | 05 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $493 | $625 | Not Implemented |
TN0670 # 06 Y:1999 | 06 | 1999 | USE SYNTHETIC LUBRICANT | $342 | $0 | Not Implemented |
TN0670 # 07 Y:1999 | 07 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $335 | $0 | Implemented |
TN0668 # 01 Y:1999 | 01 | 1999 | REDUCE SCRAP PRODUCTION | $674,570 | $64,500 | Implemented |
TN0668 # 02 Y:1999 | 02 | 1999 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $238,000 | $110,000 | Not Implemented |
TN0668 # 03 Y:1999 | 03 | 1999 | OPTIMIZE PLANT POWER FACTOR | $9,000 | $26,000 | Implemented |
TN0668 # 04 Y:1999 | 04 | 1999 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $7,860 | $8,370 | Implemented |
TN0668 # 05 Y:1999 | 05 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $6,300 | $1,200 | Implemented |
TN0668 # 06 Y:1999 | 06 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,696 | $0 | Implemented |
TN0668 # 07 Y:1999 | 07 | 1999 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,175 | $1,280 | Not Implemented |
TN0668 # 08 Y:1999 | 08 | 1999 | METER WASTE WATER | $1,120 | $3,300 | Implemented |
TN0668 # 09 Y:1999 | 09 | 1999 | INSULATE BARE EQUIPMENT | $940 | $540 | Implemented |
TN0668 # 10 Y:1999 | 10 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $900 | $196 | Implemented |