Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
436
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0427 # 03 Y:1991 | 03 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,945 | $2,250 | Not Implemented |
TN0427 # 04 Y:1991 | 04 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $1,007 | $460 | Not Implemented |
TN0427 # 05 Y:1991 | 05 | 1991 | INSTALL SET-BACK TIMERS | $1,764 | $0 | Not Implemented |
TN0427 # 06 Y:1991 | 06 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $916 | $0 | Not Implemented |
TN0427 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,026 | $1,212 | Not Implemented |
TN0423 # 01 Y:1991 | 01 | 1991 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $224,192 | $0 | Not Implemented |
TN0423 # 02 Y:1991 | 02 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,443 | $2,415 | Not Implemented |
TN0423 # 03 Y:1991 | 03 | 1991 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $974 | $285 | Not Implemented |
TN0423 # 04 Y:1991 | 04 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $310 | $0 | Not Implemented |
TN0423 # 05 Y:1991 | 05 | 1991 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $8,200 | $13,500 | Not Implemented |
TN0423 # 06 Y:1991 | 06 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,130 | $0 | Not Implemented |
TN0426 # 01 Y:1991 | 01 | 1991 | USE MINIMUM STEAM OPERATING PRESSURE | $10,911 | $500 | Implemented |
TN0426 # 02 Y:1991 | 02 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,789 | $1,000 | Implemented |
TN0426 # 03 Y:1991 | 03 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $897 | $25 | Implemented |
TN0426 # 04 Y:1991 | 04 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $327 | $45 | Implemented |
TN0426 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $400 | Implemented |
TN0426 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $360 | $940 | Implemented |
TN0426 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $345 | $556 | Implemented |
TN0426 # 08 Y:1991 | 08 | 1991 | OPTIMIZE PLANT POWER FACTOR | $803 | $1,375 | Implemented |
TN0428 # 01 Y:1991 | 01 | 1991 | REPLACE GASOLINE WITH DIESEL, LPG, OR NATURAL GAS | $217,463 | $0 | Not Implemented |
TN0428 # 02 Y:1991 | 02 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $361 | $984 | Not Implemented |
TN0428 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $11,136 | $0 | Not Implemented |
TN0428 # 04 Y:1991 | 04 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $8,847 | $0 | Not Implemented |
TN0428 # 05 Y:1991 | 05 | 1991 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $73 | $75 | Not Implemented |
TN0428 # 06 Y:1991 | 06 | 1991 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $2,021 | $500 | Not Implemented |