IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,950

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0382 # 08 Y:1989 08 1989 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $115 $600 Implemented
TN0382 # 09 Y:1989 09 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $354 $900 Implemented
TN0382 # 10 Y:1989 10 1989 DISCONNECT BALLASTS $137 $221 Implemented
TN0382 # 11 Y:1989 11 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $137 $490 Implemented
TN0385 # 01 Y:1989 01 1989 INSTALL TIMERS AND/OR THERMOSTATS $4,216 $560 Not Implemented
TN0385 # 02 Y:1989 02 1989 INSULATE BARE EQUIPMENT $3,071 $2,300 Not Implemented
TN0385 # 03 Y:1989 03 1989 KEEP LAMPS AND REFLECTORS CLEAN $8,857 $10,432 Not Implemented
TN0385 # 04 Y:1989 04 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,224 $10,400 Implemented
TN0385 # 05 Y:1989 05 1989 REPAIR AND ELIMINATE STEAM LEAKS $1,210 $380 Implemented
TN0385 # 06 Y:1989 06 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,251 $270 Implemented
TN0385 # 07 Y:1989 07 1989 INSTALL SET-BACK TIMERS $3,648 $0 Implemented
TN0385 # 08 Y:1989 08 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,449 $0 Implemented
TN0385 # 09 Y:1989 09 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $517 $301 Implemented
TN0377 # 01 Y:1989 01 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $25,781 $2,304 Implemented
TN0377 # 02 Y:1989 02 1989 INSULATE BARE EQUIPMENT $8,728 $2,428 Not Implemented
TN0377 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $19,212 $0 Implemented
TN0377 # 04 Y:1989 04 1989 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,433 $17,200 Implemented
TN0377 # 05 Y:1989 05 1989 REPAIR AND ELIMINATE STEAM LEAKS $3,364 $240 Implemented
TN0377 # 06 Y:1989 06 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,146 $800 Implemented
TN0377 # 07 Y:1989 07 1989 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,960 $200 Implemented
TN0377 # 08 Y:1989 08 1989 KEEP LAMPS AND REFLECTORS CLEAN $3,394 $11,235 Not Implemented
TN0377 # 09 Y:1989 09 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,489 $3,870 Implemented
TN0379 # 01 Y:1989 01 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $23,137 $2,100 Not Implemented
TN0379 # 02 Y:1989 02 1989 KEEP LAMPS AND REFLECTORS CLEAN $20,544 $37,163 Not Implemented
TN0379 # 03 Y:1989 03 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $2,703 $0 Not Implemented