Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,108
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0625 # 06 Y:2001 | 06 | 2001 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,363 | $100 | Not Implemented |
UD0625 # 07 Y:2001 | 07 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,047 | $3,000 | Not Implemented |
UD0625 # 08 Y:2001 | 08 | 2001 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $835 | $3,323 | Implemented |
UD0624 # 01 Y:2001 | 01 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $29,813 | $10,710 | Not Implemented |
UD0624 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,975 | $13,704 | Implemented |
UD0624 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $980 | $414 | Implemented |
UD0624 # 04 Y:2001 | 04 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $281 | $500 | Not Implemented |
UD0623 # 01 Y:2001 | 01 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $32,488 | $128,084 | Not Implemented |
UD0623 # 02 Y:2001 | 02 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $13,412 | $700 | Implemented |
UD0623 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,127 | $196 | Implemented |
UD0623 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $3,421 | $11,978 | Not Implemented |
UD0623 # 05 Y:2001 | 05 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,301 | $1,000 | Not Implemented |
UD0623 # 06 Y:2001 | 06 | 2001 | MINIMIZE WATER USAGE | $1,740 | $22 | Implemented |
UD0623 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,534 | $1,619 | Implemented |
UD0623 # 08 Y:2001 | 08 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $756 | $3,000 | Implemented |
UD0623 # 09 Y:2001 | 09 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $675 | $225 | Not Implemented |
UD0623 # 10 Y:2001 | 10 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $641 | $436 | Not Implemented |
UD0622 # 01 Y:2001 | 01 | 2001 | $12,500 | $2,500 | Implemented | |
UD0622 # 02 Y:2001 | 02 | 2001 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $9,526 | $3,323 | Not Implemented |
UD0622 # 03 Y:2001 | 03 | 2001 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $5,610 | $3,200 | Not Implemented |
UD0622 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,574 | $6,830 | Implemented |
UD0622 # 05 Y:2001 | 05 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,978 | $9,800 | Not Implemented |
UD0622 # 06 Y:2001 | 06 | 2001 | INSTALL SKYLIGHTS | $1,341 | $4,455 | Not Implemented |
UD0622 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $67 | $170 | Implemented |
UD0621 # 01 Y:2001 | 01 | 2001 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $39,420 | $0 | Not Implemented |