Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
207
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0956 # 05 Y:2016 | 05 | 2016 | OPTIMIZE PLANT POWER FACTOR | $8,199 | $12,220 | Not Implemented |
UD0956 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,229 | $0 | Not Implemented |
UD0956 # 07 Y:2016 | 07 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,566 | $24,600 | Not Implemented |
UD0956 # 03 Y:2016 | 03 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,897 | $12,000 | Not Implemented |
UD0956 # 01 Y:2016 | 01 | 2016 | INSTALL TURBULATORS | $15,641 | $5,625 | Not Implemented |
UD0956 # 11 Y:2016 | 11 | 2016 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,070 | $2,500 | Not Implemented |
UD0956 # 02 Y:2016 | 02 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,421 | $14,000 | Not Implemented |
UD0955 # 09 Y:2016 | 09 | 2016 | USE RADIANT HEATER FOR SPOT HEATING | $3,109 | $9,840 | Not Implemented |
UD0955 # 05 Y:2016 | 05 | 2016 | COMBINE UTILITY METERS | $2,301 | $0 | Not Implemented |
UD0955 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $319 | $1,000 | Not Implemented |
UD0955 # 01 Y:2016 | 01 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $191 | $0 | Not Implemented |
UD0955 # 03 Y:2016 | 03 | 2016 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $15,101 | $15,500 | Not Implemented |
UD0955 # 04 Y:2016 | 04 | 2016 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,343 | $1,152 | Not Implemented |
UD0955 # 10 Y:2016 | 10 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,366 | $23,200 | Not Implemented |
UD0955 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $260 | $17 | Not Implemented |
UD0955 # 08 Y:2016 | 08 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,363 | $21,980 | Not Implemented |
UD0955 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $15,783 | $5,438 | Not Implemented |
UD0954 # 04 Y:2016 | 04 | 2016 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $297 | $468 | Not Implemented |
UD0954 # 08 Y:2016 | 08 | 2016 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $97 | $336 | Not Implemented |
UD0954 # 06 Y:2016 | 06 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $1,258 | $3,250 | Implemented |
UD0954 # 07 Y:2016 | 07 | 2016 | INSTALL OCCUPANCY SENSORS | $3,097 | $6,944 | Not Implemented |
UD0954 # 05 Y:2016 | 05 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,273 | $0 | Implemented |
UD0954 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,397 | $1,000 | Not Implemented |
UD0954 # 01 Y:2016 | 01 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,653 | $42 | Not Implemented |
UD0954 # 03 Y:2016 | 03 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $1,140 | $378 | Not Implemented |