IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

53

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0788 # 11 Y:2008 11 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $372 $0 Implemented
UD0788 # 01 Y:2008 01 2008 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $49,954 $12,500 Implemented
UD0788 # 07 Y:2008 07 2008 INSTALL OCCUPANCY SENSORS $2,123 $3,500 Implemented
UD0788 # 09 Y:2008 09 2008 UPGRADE CONTROLS ON COMPRESSORS $1,037 $200 Implemented
UD0788 # 10 Y:2008 10 2008 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $590 $0 Implemented
UD0788 # 08 Y:2008 08 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,134 $7,000 Not Implemented
UD0788 # 02 Y:2008 02 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $44,342 $0 Not Implemented
UD0788 # 03 Y:2008 03 2008 OPTIMIZE PLANT POWER FACTOR $26,537 $21,250 Implemented
UD0788 # 04 Y:2008 04 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $20,385 $440 Implemented
UD0788 # 05 Y:2008 05 2008 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $17,084 $0 Not Implemented
UD0788 # 06 Y:2008 06 2008 AIR CONDITION ONLY SPACE NECESSARY $13,860 $0 Implemented
UD0782 # 01 Y:2008 01 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $28,951 $0 Implemented
UD0782 # 07 Y:2008 07 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,243 $1,800 Implemented
UD0782 # 09 Y:2008 09 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,907 $1,000 Implemented
UD0782 # 06 Y:2008 06 2008 ADD AREA LIGHTING SWITCHES $3,233 $10,000 Implemented
UD0782 # 05 Y:2008 05 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,643 $0 Not Implemented
UD0782 # 04 Y:2008 04 2008 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $4,245 $0 Implemented
UD0782 # 03 Y:2008 03 2008 USE RADIANT HEATER FOR SPOT HEATING $5,068 $20,000 Not Implemented
UD0782 # 08 Y:2008 08 2008 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,292 $2,000 Not Implemented
UD0782 # 02 Y:2008 02 2008 INSTALL OCCUPANCY SENSORS $5,748 $6,528 Implemented
UD0781 # 11 Y:2008 11 2008 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $800 $0 Implemented
UD0781 # 10 Y:2008 10 2008 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD $1,794 $0 Implemented
UD0781 # 01 Y:2008 01 2008 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $15,217 $4,000 Not Implemented
UD0781 # 02 Y:2008 02 2008 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $9,566 $5,000 Implemented
UD0781 # 03 Y:2008 03 2008 USE RADIANT HEATER FOR SPOT HEATING $6,695 $2,100 Not Implemented