Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0395 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,009 | $2,080 | Implemented |
UD0395 # 03 Y:1993 | 03 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,731 | $0 | Implemented |
UD0395 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,051 | $8,096 | Implemented |
UD0395 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,516 | $1,200 | Implemented |
UD0395 # 07 Y:1993 | 07 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,563 | $10,625 | Implemented |
UD0420 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,048 | $2,456 | Implemented |
UD0420 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $25,572 | $16,000 | Implemented |
UD0420 # 06 Y:1993 | 06 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,897 | $3,000 | Implemented |
UD0419 # 07 Y:1993 | 07 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $89,581 | $20,000 | Implemented |
UD0419 # 05 Y:1993 | 05 | 1993 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $81,110 | $0 | Implemented |
UD0419 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,200 | $5,739 | Implemented |
UD0419 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $19,715 | $13,400 | Implemented |
UD0418 # 02 Y:1993 | 02 | 1993 | OPTIMIZE PLANT POWER FACTOR | $14,702 | $9,250 | Implemented |
UD0418 # 03 Y:1993 | 03 | 1993 | INSTALL EFFICIENT RECTIFIERS | $1,456 | $15,000 | Implemented |
UD0418 # 05 Y:1993 | 05 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $31,259 | $6,000 | Implemented |
UD0418 # 04 Y:1993 | 04 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,180 | $4,000 | Implemented |
UD0418 # 06 Y:1993 | 06 | 1993 | RECOVER AND REUSE COOLING WATER | $12,300 | $1,000 | Implemented |
UD0416 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,163 | $2,170 | Implemented |
UD0416 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $9,061 | $3,000 | Implemented |
UD0415 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,314 | $31,350 | Implemented |
UD0415 # 02 Y:1993 | 02 | 1993 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $8,020 | $3,000 | Implemented |
UD0414 # 05 Y:1993 | 05 | 1993 | INSTALL SET-BACK TIMERS | $1,689 | $1,500 | Implemented |
UD0414 # 01 Y:1993 | 01 | 1993 | PAY UTILITY BILLS ON TIME | $2,100 | $0 | Implemented |
UD0414 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,246 | $14,248 | Implemented |
UD0414 # 04 Y:1993 | 04 | 1993 | INSTALL SET-BACK TIMERS | $1,773 | $500 | Implemented |