Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,929
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0358 # 09 Y:2005 | 09 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $4,719 | $8,000 | Implemented |
UF0358 # 10 Y:2005 | 10 | 2005 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,430 | $4,800 | Not Implemented |
UF0358 # 11 Y:2005 | 11 | 2005 | PAY UTILITY BILLS ON TIME | $856 | $0 | Implemented |
UF0357 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,460 | $65,755 | Implemented |
UF0357 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,558 | $1,105 | Implemented |
UF0357 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,371 | $1,560 | Implemented |
UF0357 # 04 Y:2005 | 04 | 2005 | ADD AREA LIGHTING SWITCHES | $571 | $2,910 | Not Implemented |
UF0357 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $448 | $0 | Implemented |
UF0357 # 06 Y:2005 | 06 | 2005 | RECYCLE FLUORESCENT LAMPS | $1,424 | $3,496 | Implemented |
UF0356 # 01 Y:2005 | 01 | 2005 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $0 | $150,000 | Not Implemented |
UF0356 # 02 Y:2005 | 02 | 2005 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,843 | $21,108 | Implemented |
UF0356 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,348 | $2,000 | Implemented |
UF0356 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,008 | $700 | Implemented |
UF0356 # 05 Y:2005 | 05 | 2005 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,918 | $1,185 | Not Implemented |
UF0356 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,295 | $2,194 | Implemented |
UF0356 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $1,232 | $1,450 | Implemented |
UF0356 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $96 | $245 | Implemented |
UF0356 # 09 Y:2005 | 09 | 2005 | RECYCLE FLUORESCENT LAMPS | $0 | $3,496 | Implemented |
UF0355 # 01 Y:2005 | 01 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $14,486 | $80,890 | Implemented |
UF0355 # 02 Y:2005 | 02 | 2005 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,072 | $93,200 | Implemented |
UF0355 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,438 | $478 | Implemented |
UF0355 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $23,786 | $0 | Not Implemented |
UF0355 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,000 | $23,755 | Implemented |
UF0355 # 06 Y:2005 | 06 | 2005 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $12,491 | $50,000 | Implemented |
UF0355 # 07 Y:2005 | 07 | 2005 | RECYCLE FLUORESCENT LAMPS | $625 | $3,496 | Implemented |